CSI ALFA LAVAL GHH-10 Instruction Manual Download Page 5

I nstal latio n 

Mounting 

The pump is delivered as a complete unit;  no 

alignment is required. 

The pump should be mounted so that it is easily 

accessible for maintenance and service. 

Check that there is sufficient room for disassem­

bly and assemb.

ly and for the installation of the 

piping. 

Pipe System 

Suction  and  discharge  lines  should  have  at 

least the same diameter as the respective con­

nection.  The suction side should have as few 

elbows  as possible.  Insure there are not  any 

leaks in the suction lines. 

Conical reducers should be used when line size 

differs from pump connections.  Use eccentric, 

conical reducers with  the  straight  side  up  on 

suction !ines. 

Lines - Connections 

Moving The Pump 

Install  the  pump  so that  the  liquid enters  the  The shroud, if fitted, should be removed before 

pump  through  the  front  connection  (suction  the pump is lifted or moved. 

branch) and !eaves through the top connection 

(discharge branch). 

Pre-Start  Up Checklist 

Install the pump so that it does not suck in 

air. 

The lines  should  be installed properly so  that 

there is no strain on the pump casing when the 

connections are tightened. 

The lines should be installed so that they do not 

cause any strain on the pump casing because of 

their thermal expansion. 

Line vibrations,  thermal  expansion  of straight 

1. Disassemble pump casing and impeller.

2. Start and stop the motor quickly and check

the direction of rotation.

The correct direction of rotation is counter 

clockwise as seen from the inlet side. 

3. Thread on the impeller and hand tighten [t

until there is metal-to-metal contact between

the impeller and the stop on the shaft.

lines,  welding close to  the  pump  or abnormal  4.  Mount the casing again and hand tighten the

strain caused by someone standing on the lines 

wing nuts firmly. 

can all cause damage to the pump casing. 

G/H Products Corp. cannot be held respon­

sible  for  damage due to  improper  installa­

tion by the customer. 

Note: 

The  pump  should  not  under  any  circum­

stance be started in  the  wrong direction of 

rotation with the impeller installed. If so ,the 

pump may be severly damaged or cause se­

rious injuries. 

CONTACT CSI FOR MORE INFORMATION  |  CSIDESIGNS.COM  |  [email protected]  |  417.831.1411

Summary of Contents for ALFA LAVAL GHH-10

Page 1: ...INSTRUCTION MANUAL IM 70737 E1 USA 9011 WE RESERVE THE RIGHT TO MINOR CHANGES IN DESIGN AND FUNCTION G H...

Page 2: ...18 03 p 1 06 1 06 1 06 Q 3 47 3 47 3 47 R 12 32 12 32 13 31 s 5 51 5 51 7 48 E N 5 Hp 7 Hp 184 TC 213 TC 5 50 5 5 12 19 13 11 12 60 14 17 9 53 11 02 9 72 9 72 5 59 5 59 8 35 9 09 5 87 6 61 18 98 20 6...

Page 3: ...3 12 95 12 95 12 95 12 95 8 35 8 35 8 35 8 35 10 08 10 08 10 91 10 91 8 03 8 03 8 03 8 03 30 16 30 16 30 16 30 16 2 63 2 63 2 63 2 63 4 96 4 96 4 96 4 96 16 58 16 58 17 39 17 39 10 00 10 00 11 00 11 0...

Page 4: ...CONTACT CSI FOR MORE INFORMATION CSIDESIGNS COM SALES CSIDESIGNS COM 417 831 1411...

Page 5: ...The lines should be installed properly so that there is no strain on the pump casing when the connections are tightened Thelines should be installed so that they do not cause any strainonthe pump casi...

Page 6: ...may take a set after a period of time so that it does not seal If swelling occurs this indicates that a wrong rubber material has probably been used The casing O ring should then be replaced by an O...

Page 7: ...livered with stainless steel nippel and adaptor to 1 4 plastic tubing Water Water consumption approximately 1 4 1 2 as min Water pressure maximum 15 PSI abo ve the inlet pressure of the pump Steam The...

Page 8: ...orp Motor NEMA Should it be necessary to replace the motor in most cases this can be done without replacing any other parts if the motor meets the demands of the standard It is important to check the...

Page 9: ...Seal alternatives Single seal Single Flushed Double flushed Viton not suitable in connection with steam 1 Order with Viton 2 Order with EPDM 3 Order with Silicone Carbide 4 Specify double flushed sea...

Page 10: ...is 3 8 3 4 15 I Assembly And Disassembly Tighten screws 3 evenlybut no more than to allow the stub shaft to be moved on mo tor shaft by knocking gently with a plastic hammer Fit adapter 13 on the mot...

Page 11: ...l ring on the drive ring 14 Pre fit the rotatingseal ring with spring into place so that the driver on the drive ring is located in the notch on the rotating seal Release this assembly carefully so th...

Page 12: ...ring 17 Replace rotating seal ring Make sure that the driver in the driving ring is di rectly opposite the notch in the seal ring and check that the spring 18 is correctly positioned 9 Fit O ring 9 o...

Page 13: ...ub shaft By knocking gently with a plastic hammer on impeller move stub shaft further onto motor shaft until the distance between im peller and back plate is 0 02 Check dis tance with a feeler gauge o...

Page 14: ...Be very careful that the driver on the driving ring enters the notch in the rota ting seal ring 18 Secure with washers 17 and nuts 16 Tighten 19 Screw impeller 33 onto stub shaft Fit im peller retaini...

Page 15: ...de the new rotating seal ring 11 Replace rotating seal ring Make sure that the driver in the driving ring is di rectly opposite the notch in the seal ring and check that the spring 10 is correctly pos...

Page 16: ...CONTACT CSI FOR MORE INFORMATION CSIDESIGNS COM SALES CSIDESIGNS COM 417 831 1411...

Page 17: ...mpeller 9612 1312 05 9612 1312 05 9612 1312 05 Legs 26a 1 Support bar right 31460 1287 6 31460 1287 6 31460 1287 5 26b 1 Support bar left 31460 1288 6 31460 1288 6 31460 1288 5 27 4 Leg 31460 1018 1 3...

Page 18: ...2 1364 01 12 0 ring FPM 9611 99 2146 Shaft seal comp PTFE 9612 1296 04 8 1 Stationary seal ring 9612 1378 01 stainless steel 9 0 ring PTFE 9611 99 2152 10 Spring 9612 1376 01 11 Rotating seal ring car...

Page 19: ...27__ Centrifugal Pump Type GHH 1 o Single Flused Shaft Seal 25 19 Reg 2 1 SP70737 2 GH 9011 CONTACT CSI FOR MORE INFORMATION CSIDESIGNS COM SALES CSIDESIGNS COM 417 831 1411...

Page 20: ...9612 1336 02 9612 1337 02 9611 99 2032 9612 1331 02 9611 99 0622 9612 1397 01 9612 1345 01 2210948 34 223107 22 9611 99 0353 9611 99 0786 9612 1311 09 31460 1309 1 9611 99 2302 9612 1384 16 9611 99 2...

Page 21: ...nless steel 9 0 ring FPM 9611 99 2150 1O Spring 9612 1376 01 11 Rotating seal ring carbon 9612 1364 01 12 0 ring FPM 9611 99 2146 Shaft seal compl PTFE 9612 1296 04 8 1 Stationaryseal ring 9612 1378 0...

Page 22: ...27 1 Centrifugal Pump Type GHH 10 Single Shaft Seal Industrial 21 Reg 2 1 SP70737 3 GH 9011 25 CONTACT CSI FOR MORE INFORMATION CSIDESIGNS COM SALES CSIDESIGNS COM 417 831 1411...

Reviews: