ELECTRICAL CONNECTION

Make the electrical connection only after the hydraulic connection has been completed; set up the motor 

control system in conformity with the technical standards and regulations in force (EN 60204-1): in par

-

ticular a manual electric power switch must be installed with adequate current switching capacity; devices 

for overcurrent and overload protection (e.g. fuses, automatic switches, etc.) must also be fitted, plus, if 

necessary, a device to prevent accidental restarting.

Check that the main frequency and voltage and the available power are suitable for the motor installed. All 

the material used for the electrical connection (cables, cable clamps, switches and  shielding) must have  

a suitable level of protection for the environment in which it is installed. Be sure to use cables of sufficient 

cross-section for the current shown on the motor plate so as to prevent them from overheating. 

Before doing anything else, make the motor's earth connection, using the terminal on the motor and a cable 

of sufficient cross-section. The cables may be connected to the terminal board using either a delta or star 

arrangement. Follow the data given on the motor plate for the main voltage, as shown in the diagram in 

pict.4; ensure that the terminals are clean and tight and not under stress.

When starting, the motor's current absorption increases briefly to 5-6 times the nominal value. If the mains 

supply is unable to substain this increase in absorption, use a star-delta starter or other kind of device 

(e.g. an autotransformer).

Pict.4 

Lower 

voltage

Higher 

voltage

C.S.F. Inox S.p.A. will accept no responsibility for damage to property and/or injury to persons caused by 

failure to comply with technical standards and regulations in force.

8 OPERATION

 8.1 

PRELIMINARY OPERATIONS

- Check that the pump turns freely under hand pressure.

Check that the clamp joining the pump casing and the cover is well tightened and that it cannot be eas

-

ily unscrewed by hand. 

The tightening of the clamp must be carried out by means of a key and NOT by 

hand.

- Check that the pump turns in the marked direction (CLOCKWISE, as seen from the control end).

- The suction pipe and the pump must be filled with liquid. There are two possible cases:

a) When the pump is to operate with a negative suction head, it must be primed by introducing liquid into 

the pump body.

b) When the pump is to operate below the level of the suction liquid, i.e. with a positive head, the suction 

and discharge gate valves must be opened until the pressure gauge on the pump discharge shows a 

pressure corresponding to the positive suction head.

- If the sealing chamber is to be cooled, open the cooling water supply and adjust the flow.

 8.2 

STARTING

-  Carry out the preliminary operations, then close the discharge gate valve completely and make sure that 

the suction gate valve is completely open.

-  Start the pump and check once again that it rotates in the right direction.

Summary of Contents for CN 2

Page 1: ...TECHNICAL SERVICE 39 0522 869832 CENTRIFUGAL PUMPS CN Series INSTRUCTIONS FOR INSTALLATION OPERATION AND MAINTENANCE...

Page 2: ...erring 5 DESCRIPTION 5 1 Sound pressure level 6 NON PERMITTED USES 7 INSTALLATION 7 1 Suction and inflow conditions 7 2 Piping 7 3 Electrical connection 8 OPERATION 8 1 Preliminary operations 8 2 Star...

Page 3: ...us or toxic liquids are pumped When pumping liquids at a temperature over 60 C adequate protection and warning signals are requi red When you buy a pump with bare shaft motor coupling operations have...

Page 4: ...aser Commercial parts incorporated in C S F products are guaranteed by their corresponding manufacturers 4 GOODS TRANSPORTATION RECEIVING AND TRANSFERRING 4 1 TRANSPORTATION The packings of all pumps...

Page 5: ...NOT BE USED IN ENVIRONMENTS WHICH REQUIRE A HIGHER LEVEL OF PROTECTION OR A HIGHER SPECIFICATION MOTOR OR ELECTRICAL PARTS Components complying with the safety standards for the environment in questi...

Page 6: ...air from entering the pump For this reason when sucking from a tank located at a lower level the pipe must reach below the free surface of the liquid In order to prevent the formation of vortices and...

Page 7: ...efly to 5 6 times the nominal value If the mains supply is unable to substain this increase in absorption use a star delta starter or other kind of device e g an autotransformer Pict 4 Lower voltage H...

Page 8: ...al and material are chosen according to the liquid to be pumped 9 1 MECHANICAL SEALS A mechanical seal is a device intended to retain fluid and prevent it from escaping from the pump The seal consists...

Page 9: ...entering from the mechanical seal Replace the mechanical seal or arrange a solution with a vacuum spring in case of vacuum suction operation 4 Obstructions present along suction pipes or valves close...

Page 10: ...cleaning when using fluids which tend to crystallize Increase washing cycles and don t leave the product laying inside the pump for a long time 27 Misassembly of the mechanical seal Assemble the mecha...

Page 11: ...pag 11 TROUBLE POSSIBLE CAUSES AND NECESSARY OPERATIONS TO SOLVE THEM A B C D E F G H I L M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39...

Page 12: ...14 anti clockwise 1 with a pneumatic wrench 2 with spanner or blocking the pump shaft from motor side Remove the impeller 3 and the key 15 Extract the rotary part of the mechanical seal 7 and turn it...

Page 13: ...ess steel could be damaged by corrosion Alkaline detergent A sodium hydroxide water solution may be used at concentration 1 3 at a temperature of 70 90 C a surfactant could be added to increase the ri...

Page 14: ...emperature for sterilization depending on gasket compound Temperature limits for rubber gasket Steam hot water Chemical bactericidal EPDM 121 C 82 C FPM FKM 149 C 82 C Impeller nut cleaning and steril...

Page 15: ......

Page 16: ...in this publication are indicative and do not bin ding C S F does not stand surety or undertake any obligation for the utilisation of this document and for the information contained In particular it d...

Reviews: