1
Disinfect the breathing bags, mouthpieces, mouthpiece
plugs, breathing hoses, snapper clamps, threaded
hose connectors with gaskets, and nose clamps using
Airkem
A
-33 or an equivalent disinfectant.
2
Mix the disinfectant with warm water (no hotter
than 110°
F
), according to the manufacturer’s
recommendations, in a clean container.
3
Soak the components (breathing bags, mouthpieces,
mouthpiece plugs, breathing hoses, snapper clamps,
threaded hose connectors with gaskets, and nose clamps)
in the disinfectant solution for at least 10 minutes.
4
Rinse the components in clean, warm (no hotter than
110° F) water to remove all traces of disinfectant.
5
If you plan to reuse the components immediately,
remove the excess water and hand-dry them.
6
If you plan to store the components, air-dry them
before placing them in storage. Store them in sealed
transparent bags or containers, marked with the
words “Used and Disinfected” and the date they
were placed in storage.