Fireplace Installation
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and
wire the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired.
In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or
the current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
A.
Remove the cover plate from the right side
B.
Remove the wire connectors from the power
bottom of the appliance by removing the three
screws, as shown above.
cord. The power cord may be discarded.
C.
Take the new cover plate, supplied in the hardware bag. Punch out the 7/8" (22.2mm) hole and
install
a box connector through, into the junction box. Snap the box connector clamp onto the supply
wires.
D.
Using the wire connectors, connect the ground green wires (G), the common white wires
(N) together, then the hot black wires (L) and then the refer to Figure 3.
E.
Re-install the cover plate using the three screws, as shown in Figure 1.