TECHNICAL DATA:
Performance data at 6 bar operating pressure
5 1212 0050
aluminum body
5 1213 0010
steel housing
Cutting capacity for pipes
Cutting capacity for profiles
dia. mm
dia. mm
530
290
Stroke number (under load)
1/min.
330
Stroke of saw blade
mm
60
Motor output
kW
1.1
Air consumption
M
3
/min. 1.45
Air connection
R ¾” male
ID of hose
mm
13’
Weight kg
6,40
10,65
Length mm
570
OPERATING INSTRUCTIONS:
Pneumatic
Hack
Saw Type 5 1212 …. and 5 1213 ….
The service life and performance for this machine is determined mainly by:
a) the purity of the air
b) the lubrication conditions and maintenance
a) Before connecting the machine, blow out the air hose. If rust can be formed and water can be
deposited in the pipe system, a dirt and water separator should be connected before the
machine.
b) The built-in oiler should always be filled with resin and acid free lubricating oil, SAE 5 W –
SAW 10. Thick liquid oils cause the vanes to stick, and thus impair the starting and the
performance of the motor. The service life can be improved many times by optimum
lubrication. We recommend in particular therefore that service units are fitted before the
machine.
Please observe the comments in the information sheet
Maintenance of Pneumatic Tools
Enclosed and greased ball bearings must not be washed out. At the end of the working period,
flush the machine with thin liquid oil, or apply the necessary corrosion protection agent in
some other way. Clean the screen at the air inlet regularly. In winter, or if the air is very
moist, an anti-freeze lubricant, e.g. “BP-Energol AX”, “Kilfrost”, or “Kompranol N 74” should be
used.
Parts, which are subject to wear, particularly the vanes, should be replaced in good time.
They should be regarded as worn out if the width is less than 9.5 mm.
We recommend changing the grease in the gear casing aft 300 hours of operation. Use a
special-purpose gear casing grease only: