background image

 
 

Page 2 of 15 

 

** THIS UNIT MUST BE INSTALLED AND EARTHED BY A 

LICENSED PLUMBER ** 

 

 

 

WARNING   

 

To prevent risk of electric shock, make sure this system is 

 

properly earthed and protected by a safety switch. 

 

Pull the plug before servicing or replacing lamps. 

 

Keep all connections dry and off the ground. 

 

Do not touch the plug with wet hands. 

 
 

WARNING  

 

Do not look directly at the UV lamp when it is operating. 

 

The light emitted by the lamp can cause serious damage to eyes  

 

and burn unprotected skin. 

 
 
 
 

WARNING 

 

This unit must be installed by a licensed plumber. 

 

Read manual before installing or servicing the system. 

 

Only experienced technicians who possess a strong understanding  

 

of the system should attempt to replace lamps or service it. 

 
 

To guard against injury, basic safety precautions should be observed including the following: 

 

1.

 

Read and follow all safety instructions. 

2.

 

Ensure the unit is properly earthed before operating. 

3.

 

The power supply must be protected by a Residual Current Device (Safety Switch) 

4.

 

Since water is employed in the use of this system, special care should be taken to avoid possible electric shocks.  

DO NOT attempt to repair the system yourself.  Contact an authorized service facility for service. 

5.

 

DO NOT operate the system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged 

in any manner. 

6.

 

Before servicing or cleaning, unplug the system. Never pull the cord to disconnect plug from power supply. Grasp the 

plug and pull to disconnect. 

7.

 

DO NOT use the system for anything other than its intended purpose. The use of attachments or accessories not 

recommended or sold by the manufacturer may cause unsafe conditions or reduce performance. 

8.

 

Visually inspect the system prior to installation. If the quartz sleeve or lamp is broken, cracked or damaged in anyway, 

DO NOT use. 

9.

 

DO NOT plug the system into an electrical outlet without properly securing the lamp and quartz sleeve into the chamber. 

10.

 

Always shut off water flow and release water pressure before cleaning and maintaining the system. 

11.

 

Intended for indoor use only.  System MUST NOT be exposed to weather elements. 

12.

 

Installation of the system MUST be in accordance with local plumbing and electrical codes as well as any and all 

applicable regulations and laws. 

13.

 

Warranty will be VOID if the above is not followed. 

14.

 

SAVE THIS MANUAL 

 

Summary of Contents for AQUA PRO 1 GPM

Page 1: ...ULTRAVIOLET STERILISER INSTALLATION MAINTENANCE BOOKLET Crystal Clear Purification Systems Pty Ltd 81 Torrens Road BROMPTON SA 5007 Australia t 08 8340 4344 e cc crystalclearaustralia com w www crysta...

Page 2: ...to avoid possible electric shocks DO NOT attempt to repair the system yourself Contact an authorized service facility for service 5 DO NOT operate the system if it has a damaged cord or plug if it is...

Page 3: ...t does not reduce sediments which effects the efficiency of the UV lamp Water Quality Parameters Water quality is extremely important for the performance of your UV system The following levels are rec...

Page 4: ...Page 4 of 15 Components Checklist Stainless Steel Vessel Quartz Sleeve w o rings Pre installed in vessel Ballast 14W Lamp Tube x F Elbow x2 Bracket x2...

Page 5: ...al with the lamp connector on top This is to prevent water damage from occurring on the lamp pins and connector The ballast should be mounted horizontally either above or beside the chamber to prevent...

Page 6: ...le elbow fittings to inlet and outlet ports of the unit Connect fittings into water line or onto a water filter system Open water supply to the unit and open faucet Once water is pouring out of the fa...

Page 7: ...turn water supply on and switch on the power CHECK FOR LEAKS The light on the ballast should come on and turn green A red light on the ballast indicates a failed lamp and or ballast Turn the unit off...

Page 8: ...Page 8 of 15...

Page 9: ...s and disconnect inlet and outlet elbows from chamber Tip the unit and drain as much water as possible into a bucket Remove end cover from chamber disconnect wire 4 pin plug from lamp and carefully re...

Page 10: ...sel to water supply but do not turn power on Open water supply and faucet and allow unit to flush until water no longer suds System Limitations AquaPro UV systems are designed to operate continuously...

Page 11: ...est source water for turbidity may need better pre filtration HEATED PRODUCT WATER Infrequent use of water o Run water until it returns to ambient temperature CLOUDY WATER Air in lines o Run water unt...

Page 12: ...our 24 hours of delivery A copy of the original invoice must be presented for any Warranty claim as proof of purchase The faulty item must be returned to Crystal Clear if such a request is made This l...

Page 13: ...Replaced Filters changed Yes Replace next service Next Service Due ____ ____ ____ 3rd Service ____ ____ ____ Serviced By ________________________ Lamp changed Yes No Quartz sleeve condition OK Cleaned...

Page 14: ...Page 14 of 15 Notes...

Page 15: ...Page 15 of 15 Notes...

Reviews: