4. Use
17
Step 1 :
Press
to switch on your pump.
Step 2 :
Press
to switch from one mode to another until the silent mode is displayed.
Step 3 :
Using buttons
and
select the required temperature.
EXAMPLE :
If the current temperature is 18.8°C, default setting temperature is 27° required temperature is 30°C.
Current water temperature
Required water temperature
When the incoming water temperature is less than or equal to the required temperature (set point
temperature) -X°C, the heat pump will switch to heating mode. The compressor will stop when the
temperature of the incoming water is greater than or equal to the required temperature (set point
temperature).
Temperature deviation value X setting
X : adjustable parameter from 1° to 18°C, default setting of temperature deviation value is 1°C.
(Parameter
“P01”)
Step 1 :
Press
to switch on your pump.
Step 2 :
Press
to switch from one mode to another until the auto mode is displayed.
4.6
Auto mode
Useful information about how the silent mode operates
4.5