Crystal Vision
Hardware Installation
ShARC-XPUserManualR2.11
8
21/09/05
BNC
Function
N/C
No connection
SDI IN
Serial digital input
N/C
No connection
SDI OUT (A)
Serial digital output
SDI OUT (B)
Serial digital output
N/C
No connection
RM01 modular rear connector for ShARC204-XP
Description
SDI OUT (2B) SDI OUT (1B) SDI OUT (1A) SDI IN (2) SDI IN (1) SDI OUT (2A)
ZLA00298 ShARC204-XP
RM01
RM01(ZLA00298 artwork)
•
24 ShARC-XP modules per
4U Indigo 4 frame
•
12 per 2U Indigo 2 frame
•
Six per 1U Indigo 2 frame
•
Two in an Indigo desk top box
•
All frame slots can be used
Note:
One ShARC-XP card can be fitted to each RM01 rear module.
BNC
Function
SDI OUT (2A)
Channel 2 serial digital output 2 (ShARC204-XP only)
SDI IN (1)
Channel 1 serial digital input
SDI IN (2)
Channel 2 serial digital input (ShARC204-XP only)
SDI OUT (1A)
Channel 1 serial digital output 2
SDI OUT (1B)
Channel 1 serial digital output 1
SDI OUT (2B)
Channel 2 serial digital output 2 (ShARC204-XP only)
Note:
For details of fitting rear connectors please refer to the appropriate frame manual.
2.5 General Purpose Interface (GPI)
ShARC-XP, as with most Crystal Vision modules, is equipped with GPI control I/O.
Remote control of the aspect ratio conversion mode on each channel other than via the
serial remote protocols is possible.
Remote connections
For Channel 1, DIL 1 and DIL 2 need to be in the ‘UP’ position. Jumpers on J1, J4, J16
and J17 need to be moved on to their GPI position. Remote control via auxiliary RS422
will no longer be possible. In this configuration a remote switch shorting to ground can be
as defined below. Pull-up resistors are already present.