Crystal Vision
Rear modules and signal I/O
3 Rear modules and signal I/O
The 2U Indigo 2 frames will house up to 12 single height modules and dual power
supplies. The 1U Indigo 1 frames will house six single height modules and a single or
dual power supply. The Indigo DT desk top boxes have a built-in power supply and
will house up to two single height modules. All modules can be plugged in and
removed while the frame is powered without damage.
Note:
For details of fitting rear connectors please refer to the appropriate
frame manual.
Rear module connections with RM41
The RM41 being a single height module will allow maximum packing density with the
maximum number of outputs available.
RM41 rear module connector
Description
RM41
•
12 Q-Down 3G per Indigo 2
frame
•
Six per Indigo 1 frame
•
Two per Indigo DT
•
All frame slots can be used
BNC
I/O assignment
SDI/CVBS/Y/G OUT
HD/SD SDI / CVBS, Y, G output (link PL2)
SDI/CVBS/U/B/YCY OUT
HD/SD SDI / CVBS, U, B, YC-Y output (link PL3)
SDI/CVBS/V/R/YCC OUT
HD/SD SDI / CVBS, V, R, YC-C output (link PL4)
SDI LOOP OUT
High Definition/Standard Definition serial digital input reclocked loop-
through
SDI LOOP OUT
High Definition/Standard Definition serial digital input reclocked loop-
through
SDI IN
High Definition/Standard Definition serial digital input
Rear module connections with RM57
The RM57 is a single height module used when the optical option is fitted.
RM57 rear module connector
Description
RM57
•
12 Q-Down 3G per Indigo 2
frame
•
Six per Indigo 1 frame
•
Two per Indigo DT
•
All frame slots can be used
Q-Down-AG 3G/ATG 3G User Manual R2.1
9