Crystal Vision
Trouble shooting
Indigo PSU Manual R1.1
15
16/06/2010
DC-DC converter module showing fuse carrier on the left side
If a fuse blows repeatedly this indicates a fault either in the associated power supply
module or elsewhere. Return the frame and/or power supply to the manufacturer or dealer
for repair.
Note:
Replace the fuse only with one of the same type and rating (10A, 250V time delay).
Indigo 1-DP
The Indigo 1-DP does not have externally accessible mains fuses. They are situated on the
Power supply modules. To service these fuses it is necessary to remove the power supply
module from the frame.
PS-55i showing mains fuse.
To replace the mains fuse first remove the protective cover. The fuse may then be prized
from its carrier with the aid of an instrument such as a flat bladed screwdriver. Take care
not to damage any surrounding components or wiring. Once the replacement fuse has
been inserted ensure the safety cover is replaced before refitting the module.
Note:
Replace the fuse only with one of the same type and rating (5A, 250V time delay).