Example applications
A GPI line may be configured as either an input or an output using Statesman control.
Bi-directional GPI line configured as an I/P
Note:
A low is detected at voltages below 0.8V, and a high is detected at voltages above 2.4V.
Voltages between 0.8V and 2.4V may produce either a high or low input indication.
Bi-directional GPI line configured as an O/P
Note:
A 500mA +5Volt supply may be found on the remote connectors of the frames in which
the GPI36 may be fitted.