Page 7 of 9 DTB-AV user manual issue 1.1
Statesman Mode
Press Cal to Exit
Press the Cal button on the front of the Control panel
After a few seconds the following message will be seen
Available Cards 1
xxxxx Node xx
On the bottom line of the display is the plug-in card Type and its Node number. This assumes
a card is fitted in one of the slots in the frame and is able to talk to the control panel.
Pressing Enter button will usually select the main menu page of that card
such as
ADC104F v3.00 Node00
Horiz Pos Other
If there are no plug-in cards in the Frame, the message
No cards present
Please press device
will appear.
If there are plug-in cards in the Frame and communication is unsuccessful
The message
No cards present
Please press device
will still appear. In this case recheck the Installation information. If necessary remove all cards
in the Frame except for one which the Control Panel should communicating with. Press the
Device key- the display should now show
Available Cards 1
xxxxx Node xx
On the bottom line of the display is the plug-in card Type and its Node number.
Now plug the remaining plug-in cards(with communication software EPROM fitted ) one by
one into the Frame and allow several seconds between plugging in each card, observe that
the ‘ Available Cards’ number increases by one each time. This procedure may lead to
identifying where the problem is.
Selecting different plug-in cards
At any time pressing the DEVICE key will change the Control Panel to the mode for displaying a list
of Available Cards in the system.
In the top right hand side of the display a number is shown for the total number of plug-in Cards in the
system (which have the necessary software to communicate with the Control Panel).
On the bottom line of the display is the plug-in card Type and its Node number.
To access details on any other plug-in cards turn the shaft on the front of the unit. If the number of
Available Cards is greater than 1 the display will change showing the other plug-in card details.
To
exit
the Available Cards mode press the ENTER key. The Control Panel will now ‘lock on’ and
communicate with the plug-in card at the node number last displayed in the Available Cards list.
Note The Control Panel scans, every few seconds, the two plug-in card node addresses to keep the
Available Cards list up to date
.