Crystal Quest CQE-WH-01100 Installation And Operation Manual Download Page 4

Please note all drawings, pictures, colors and sizes are approximate for illustrative purposes only and may not 

exactly resemble the end product. 

NOTE: Be sure to allow a minimum space of 1-1/2” to 2” under the filter for removing the sump.

NOTE: It is recommended that a shut-off valve be placed on both sides of the filter. 

NOTE: It is recommended that a Whole House Leak Detector Smart Valve (CQE-WH-03064) be placed directly upstream 

of your household filter to prevent water damage.

*Measure to shoulder inside of fittings. Copper pipe butts against this shoulder. 

Minimum Materials Needed

•    2 sweat adapters, ¾” or 1” 

      NPT x sweat (sweat end to fit 

      existing pipe)

•    Lead-free solder and flux

•    Soldering torch

•    Tubing cutter

•    Thread seal tape

•    Sandpaper or emery cloth 

      open end (to fit sweat adapter) 

      or adjustable jaw wrench

INSTALLATION ON WHOLE HOUSE MAIN WATER PIPE USING SOLDERED COPPER FITTINGS

STEP 1

Preparing to Install

STEP 5

Attaching Soldered Fittings to Filter Head

STEP 6

Installing the Unit

STEP 7

Final Check

STEP 2

Cutting the Pipe

STEP 3

Installing the Mounting Bracket

STEP 4

Attaching Soldered Copper 

Fittings to Filter Housing

CAUTION: 

Heat created when soldering

 

can damage the water filter housing. Be 

sure to use the following procedures to 

protect the water filter. 

•    Turn off the water supply and open a 

      nearby faucet to drain the water out of 

      pipes. 

NOTE:

 Have a bucket and towel available to 

collect excess water. Remove the nut and 

brass ferrule from both compression fittings 

and set aside. Using a tape measurer or 

ruler, measure the distance “X”.* Mark these 

dimensions so you do not forget. 

•    Remove the sump from the filter head and set the sump aside. 

•    After the sweat adapter cools, apply several wraps of Teflon® 

      tape to the threads on the sweat adapter fitting. 

•    Carefully turn the filter head INLET (if water flow is from the left) 

      onto the sweat adapter fitting. If water flow is from the right, 

      turn the outlet side of the head onto the fitting. DO NOT 

      cross-thread or overtighten. This will cause damage to the 

      threads and crack the head. 

•    Mark the distance of “X” on a length of copper pipe. Cut the 

      length of pipe. 

•    Remove the sweat adapter fitting from the filter head and solder 

      to the cut length of pipe. 

•    After the sweat adapter cools, apply several wraps of Teflon® 

      tape to the threads on the sweat adapter fitting. Apply flux and 

      place the pipe end of the soldered assembly into the straight 

      connector, then turn the adapter end into the filter head and 

      tighten. 

•    Solder both sides of the straight connector.

•    Before replacing the sump and turning on the water supply, 

      install the filter cartridge. Tighten filter housing to seal (refer to 

      

Changing Cartridges

 section). 

•    Install filter if not already done (refer to 

      Changing Cartridges

 section).

•    Slowly turn on water supply. 

•    Check entire system for leaks. 

•    If the system leaks from the fittings, shut 

      off the water flow and tighten or reseal 

      the fittings. If the system leaks from the 

      filter housing, tighten the housing with a 

      wrench. 

•    After installation, flush the cartridge for 

     10 minutes. Wait one hour, then flush 

     again for 10 minutes before use. 

Refer to 

Installing the Ground Wire 

section 

before cutting the pipe. 

•    Select a secure location surface to install 

      filter and mounting bracket. The location 

      should align the filter system with inlet 

      and outlet pipe and should not cause 

      the pipes to bend or become damaged. 

      Mark the distance “X” on the pipe. 

•    Using a pipe cutter, cut pipe. Sand (file) 

      cut ends of pipe to ensure that they are 

      square and smooth. 

•    The bracket can be used as a template 

      for marking the location of the mounting 

      screws. 

•    Use four hex washer-head screws to 

      mount bracket to the wall firmly. Use 

      proper anchors on wall. Anchors are 

      NOT included. 

•    Solder a sweat adapter onto one of the 

      pipe ends.

•    Place, but do not solder, a straight 

      connector onto the other pipe end. 

4

Summary of Contents for CQE-WH-01100

Page 1: ...Copyright 2017 Crystal Quest All rights reserved MADE IN THE USA Crystal Quest Point of Entry POE Whole House Compact Water Filter Systems INSTALLATION AND OPERATION GUIDE COMPONENTS ...

Page 2: ... unsafe or of an unknown quality without adequate disinfection before or after using the system Your Whole House Compact system will stand up to 60 pounds per square inch psi water pressure If house water supply pressure is higher than 60 psi install a working pressure reducing valve before installing system The most common residential operating range is 35 65 psi Turn off the water flow to the ho...

Page 3: ...tion for the filter that is 1 Protected from freezing 2 Not exposed to direct sunlight or high heat 2 Place a shut off valve on both sides of the filter recommended 3 Place shut off valves directly upstream of your household filter recommended 4 Place Whole House Leak Detector Smart Valve CQE WH 03064 directly upstream of your household filter to avoid water damage recommended 5 Plan your installa...

Page 4: ...water flow is from the left onto the sweat adapter fitting If water flow is from the right turn the outlet side of the head onto the fitting DO NOT cross thread or overtighten This will cause damage to the threads and crack the head Mark the distance of X on a length of copper pipe Cut the length of pipe Remove the sweat adapter fitting from the filter head and solder to the cut length of pipe Aft...

Page 5: ... the filter head if pipe lengths are not exact Align filter assembly with pipe ends With the inlet side of the water filter facing incoming water spread the pipes apart and fit both hex nipple adapters into the union fitting Turn into union fitting and tighten Using two adjustable wrenches hold incoming fitting securely with one wrench and tighten nut with second wrench Repeat the procedure on the...

Page 6: ...rnal seal and the housing seal In the event of a leak carefully examine its source Water from a leak may run along the pipe work it may drip or collect some distance from the actual location of the leak Note It is recommended that a Whole House Leak Detector Smart Valve CQE WH 03064 be placed directly upstream of your household filter to prevent water damage INSTALLATION DIAGRAM OF WHOLE HOUSE COM...

Page 7: ...QE WH 01109 Replacement Cartridges CQE RC 04030 CQE RC 04034 CQE RC 04036 10 10 Stainless Steel 2 5 x 10 CQE WH 01100 Replacement Cartridges CQE RC 04026 IMPORTANT Before first use run water through cartridge 10 minutes to prepare unit for use Be sure to allow a minimum space of 1 5 2 under the filter for removing the housing s to change the cartridge s You should change your cartridge when the wa...

Page 8: ...exclusions may not apply to you Should service be required during or after the warranty period or should you have any questions regarding how to use your CRYSTAL QUEST Whole House Compact System please contact out Technical Support Department at service crystalquest com Monday through Friday 9 AM to 5 PM Eastern Time All Crystal Quest water filtration systems should be installed by a qualified lic...

Page 9: ...ication System please contact manufacturer s Technical Support Department Monday through Friday 9 AM to 5 PM Eastern Time or your authorized CRYSTAL QUEST dealer Mailing Address FilterWater com P O Box 968 Southampton PA 18966 USA http www FilterWater com Tel 1 800 439 0263 Fax 1 215 354 0304 Email Sales filterwater com AUTHORIZED DISTRIBUTOR 9 ...

Reviews: