![Crystal Fire CF-1224-LP (NG) User Manual Download Page 4](http://html1.mh-extra.com/html/crystal-fire/cf-1224-lp-ng/cf-1224-lp-ng_user-manual_2692044004.webp)
Page | 4
www.outdoorrooms.com
1-866-303-4028 Crystal Fire 42435 REV H 4/11/12
1
Listing and Code Approvals
A. Appliance Certification
B. BTU Specifications
MODEL:
CRYSTAL FIRE CF-20-LP, CF-1224, CF-2424,
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Decorative Gas-Fired Outdoor Fireplace
STANDARD:
IAS US requirements for Outdoor gas
fireplaces, Draft 4-96 and CSA requirement for
Outdoor Gas Fireplaces, CR-97-003
The Crystal Fire has been tested in accordance with
IAS US requirements for Outdoor Gas Fireplaces,
Draft 4-96 and CSA requirement for Outdoor Gas
Fireplaces, CR-97- 003 for Canada and has been
listed by Underwriters Laboratory (UL) for installation
and operation as described in these installation and
operating instructions.
The installation must conform with local codes or, in
the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1 or CAN/CGA-B149.1,
National Gas Installation Code or CAN/CGA-
B149.2, Propane Installation Code.
Model
Orifice Size
LP NG
CF-20
CF-1224
CF-2424
Whole-house
20lb tank
#43
#43
#36
#42
#31
#31
#17
CF-1242
#31
#21
Max input
BTU
Max input
BTU
Max input
BTU
Max input
BTU
60,000 60,000
55,000 51,000
79,000
61,000
107,000
100,000
90,000