Listing and Code Approvals

    

A. Appliance Certification 

 

 

 

B. BTU Specifications  

MODEL:

 

CRYSTAL FIRE CF-20-LP, CF-1224, CF-2424, 

 

LABORATORY:

 Underwriters Laboratories, Inc. (UL) 

TYPE:

 Decorative Gas-Fired Outdoor Fireplace 

STANDARD:

 IAS US requirements for Outdoor gas 

fireplaces, Draft 4-96 and CSA requirement for 
Outdoor Gas Fireplaces, CR-97-003 

The Crystal Fire has been tested in accordance with 
IAS  US  requirements  for  Outdoor  Gas  Fireplaces, 
Draft  4-96  and  CSA  requirement  for  Outdoor  Gas 
Fireplaces,  CR-97-  003  for  Canada  and  has  been 
listed by Underwriters Laboratory (UL) for installation 
and operation as described in these installation and 
operating instructions. 

The installation must conform  with  local codes or, in 
the  absence  of  local  codes,  with  the  National  Fuel 
Gas  Code  ANSI  Z223.1  or  CAN/CGA-B149.1, 
National  Gas  Installation  Code  or  CAN/CGA-
B149.2, Propane Installation Code. 

 

Model 

Orifice Size 

     LP                         NG 

CF-20 

 
CF-1224 

 
 

CF-2424 

 

Whole-house 

20lb  tank 

#43 

#43 

#36 

#42 

#31 

#31 

#17 

CF-1242 

 

#31 

#21 

Max input 

BTU 

Max input 

BTU 

Max input 

BTU 

Max input 

BTU 

     60,000                       60,000 

     55,000                       51,000 

79,000 

61,000 

107,000 

100,000 

90,000 

Summary of Contents for CF-1224-LP (NG)

Page 1: ...upplier s Instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier HOT DO NOT...

Page 2: ...lies to all models and gas control systems Your new Crystal Fire will give you years of durable use and trouble free enjoyment Homeowner Reference Information Model name ______________________________...

Page 3: ...ralGas 9 Troubleshooting 10 Maintainingandservicingtheappliance 11 ReferenceMaterials a Servicepartslist b Limitedone yearwarranty c Contactinformation CF20 Black propane hose with regulator Flexible...

Page 4: ...utdoor Gas Fireplaces Draft 4 96 and CSA requirement for Outdoor Gas Fireplaces CR 97 003 for Canada and has been listed by Underwriters Laboratory UL for installation and operation as described in th...

Page 5: ...d the warranty will be voided by the following actions Installation and use of any damaged components Modification of the burner assembly Installation other than as instructed by the Outdoor GreatRoom...

Page 6: ...e Actual installation may vary due to individual design preference Fire Risk Provide adequate clearance Around air openings For service access Locate appliance away from traffic areas WARNING 72 inche...

Page 7: ...inches 64 5 sq cm If ventilation openings at floor level are in a side wall there must be a least two openings The bottom of the openings must be at floor level and the upper edge can t be more than...

Page 8: ...valve is turned completely off clockwise Ensure the tank valve has the proper external mating threads tank valve marked USE WITH TYPE 1 Inspect the hose shipped with the appliance for any damage Do n...

Page 9: ...wire SPK GND on page 17 of this user manual can be purchased to relocate the grounding contact point of this igniter to a nearby metal surface Once properly grounded located the black wire hanging fro...

Page 10: ...pply installed in accordance with local building codes if any If not follow ANSI 223 1 Installation should be done by a qualified installer approved and or licensed as required by the locality In the...

Page 11: ...installation location and proper sized orifice inserted in burner neck see chart on p 4 for orifice sizing locate flexible rubber propane hose and regulator supplied with this burner 2 Attach the prop...

Page 12: ...rely with two wrenches 3 At this point you have two options for plumbing natural gas If using a valve assembly such as The Outdoor GreatRoom Company s valve kit proceed to step 3a If plumbing directly...

Page 13: ...air may result in a fire or explosion D Do not use the appliance if any part has been underwater Immediately call a qualified service technician to inspect the appliance and replace any part which has...

Page 14: ...re pit with CF 1242 burner 42 Black Glass fire pit table with CF 20 burner Napa Valley fire pit table with CF 1224 burner WARNING FIRE RISK HIGH TEMPERATURES Keep combustible household items away from...

Page 15: ...B Improper air fuel mixture related to air shutter position Close air shutter 4 Metallic noise A Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound p...

Page 16: ...necessary 3 Inspect for flame problems 4 Verify air shutter is clear of dust and debris and is in correct position for the gas type being used 5 Inspect orifice for soot dirt or corrosion 6 Verify man...

Page 17: ...r CF 2424 CF 1242 LP 20lb tank CF20 LP LPK 42 1 7 Orifice LP 43 For CF 1224 LP LPK 43 1 8 Ball Valve LP SRV BV CF 1 9 On Off Valve NG SRV OO CF 1 10 Electronic Piezo CF Sparker 1 11 Gas Hose with Regu...

Page 18: ...ed or replaced before The Outdoor Greatroom Company has been afforded a reasonable opportunity to inspect the Product This warranty is limited to the replacement or repair of defective components or w...

Reviews: