background image

REVISION

BY

DATE

REV

DRAWN

NAME

SCALE

SIZE

TITLE

TELEPHONE: 651-456-9100  FAX: 651-456-9191

2955 LONE OAK CIRCLE #8, EAGAN., MN 55121

CRUSADER MANUFACTURING CORP.

2-11-07

DATE

NAME

DH

APPR.

REV

ALL DIMENSIONS IN INCHES
UNLESS NOTED

UNLESS OTHERWISE
SPECIFIED TOLERANCES ARE:

FRACTION ± 1/32
ANGLE ± 1°

.X ± .02
.XX ± .01
.XXX ± .005

   

THIRD ANGLE PROJECTION

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS DRAWING IS THE 
SOLE PROPERTY OF CRUSADER MANUFACTURING CORP.  
ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT 
THE WRITTEN PERMISION OF CRUSADER MANUFACTURING 
CORP. IS PROHIBITED.

FINISH:

MATERIAL:

DO NOT SCALE DRAWING

B

1:4

SHEET 2 OF 2

RECOVERY TANK ASSEMBLY

-

RECOVERY TANK ASSEMBLY

ITEM 

NO. QTY. UM PART NUMBER

DESCRIPTION

1

1

EA

2901

RECOVERY TANK

2

2

EA

2907

STRIKE FOR THE LATCH

3

1

EA

2912

1 1/4" MPT FITTING

4

1

EA

2913

1 1/4"  TO 3/4" REDUCER

5

1

EA

2911

3/4" STAND PIPE

6

1

EA

2914

3/4" RIGHT ANGLE ELBOW

7

1

EA

2909

BALL FLOAT SHUTOFF

8

4

EA

1001

RIVET - CLOSED END

9

4

EA

1002

3/16" WASHER FOR RIVET

10

1

EA

2910

PORT HOLE COVER ASSY

11

6

EA

1070

#8 X 3/4" COUNTERSINK SCREW

10

11

10

6

5

7

4

3

1

9

7

8

2

2

8

9

Summary of Contents for 3000B

Page 1: ...s NOT covered under warranty 3 Cleaning the unit and Storage a To empty the recovery tank first remove the vacuum hose Then release both the front and rear latches and lift off the top recovery tank b Pour out the dirty solution through the vacuum inlet This is of course after you have removed the vacuum hose from the inlet and the recovery tank from the bottom solution tank c When you are finishe...

Page 2: ...Industrial Product Limited Warranty The Crusader spotter is warranted to be free of defects in material and workmanship under normal use for a period of one 1 year from the date of manufacture The limited warranty will not apply to pumps products that were improperly installed misapplied damaged altered or are incompatible with fluids All industrial pumps products must be flushed of any chemicals ...

Page 3: ...7 1 EA 1074A 3 JUMPER W TERMINALS 4 1 1 EA 2908 SMALL SUCTION SCREEN 4 2 1 EA 2916 1 8 MPT NIPPLE 5 2 EA 1034 3 8 SPACER 6 1 EA MOTOR GROUP 85 INCH 6 1 1 EA 2904_B MOTOR PLATE 6 2 1 EA 2050 85 WATER LIFT MOTOR 6 3 1 EA 1043A MOTOR SCREEN 6 4 1 EA 2453 MOTOR GASKET W PSA 6 5 2 EA 1012 10 X 1 2 PHSMFPH TYPE A 6 6 2 EA 1006 TINNERMAN SPEED NUT 7 1 EA 2918 1 4 X 4 1 4 HOSE 8 2 EA 2915 16 HOSE CLAMP 9 ...

Page 4: ...3000B Spotter Wiring Diagram Property of Crusader Mfg Inc 2955 Lone Oak Circle 8 Eagan MN 55121 800 597 3336 www crusadermfg com ...

Page 5: ...G CORP ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISION OF CRUSADER MANUFACTURING CORP IS PROHIBITED FINISH MATERIAL DO NOT SCALE DRAWING B 1 4 SHEET 2 OF 2 RECOVERY TANK ASSEMBLY RECOVERY TANK ASSEMBLY ITEM NO QTY UM PART NUMBER DESCRIPTION 1 1 EA 2901 RECOVERY TANK 2 2 EA 2907 STRIKE FOR THE LATCH 3 1 EA 2912 1 1 4 MPT FITTING 4 1 EA 2913 1 1 4 TO 3 4 REDUCER 5 1 EA 2911 3 4 ...

Reviews: