26
❖
English
L-2028
Fig. 14 - Dedicated Power Module (DPM) Specs Tables for Use With Cuddy dc Systems Only
Electrical Specifications
Output Waveform............................................... Modified Sine-Wave
Output Power ..................................................... 600W Continuous
Output Surge Rating ......................................... 1200W for 1 sec
Output Voltage ................................................... 115VAC ± 10%
Output Frequency ............................................. 60Hz (±4Hz)
Input DC Voltage Range ................................... 11 - 15VDC
Input Low Voltage Shutdown ............................ < 10.5VDC ± 0.2VDC
High Temperature Shutdown ............................ Thermistor
≥
167°F (75°C)
Reverse Polarity Protection .............................. External Fuse
No Load Current Draw ...................................... 0.75A~0.95A
Efficiency ........................................................... ~90%
Over-voltage Shut-down ................................... 16-17VDC, restart below 16VDC
General Specifications
Isolation Voltage ................................................ Non-isolated
Operating Temperature Range ......................... -13 ~ 122°F (-25 ~ +50°C)
Storage Temperature Range ............................ -40 ~ 167°F (-40 ~ +75°C)
External Fuse .................................................... 30A x 2
Safety ................................................................. CE
Dimensions (L x W x H) .................................... 9.5 x 5.1 x 2.7" (241 x 130 x 69mm)
DC Input Connections (IN) ............................... Ring Terminals
Net Weight ......................................................... ~2.9 lbs (1.3kg)
AC Output Connections .................................... Per Dometic Wiring Diagram M8010112 in this manual
Ventilation .......................................................... Allow at least 1" (25mm) above unit for adequate airflow.
LED Lights Scheme for DPM (see note)
Battery Energy Level
No Load
With Load
Full (Battery Voltage>13V) ................................ Green ................. Green
Intermediate(12-13V) ........................................ Green ................. Orange
Low(<12V) ......................................................... Red .................... Red
Note: LED lights may or may not be readily visible, depending on DPM installation location. This table is included as a conve-
nience, but is not necessary for troubleshooting the system.
Di
s
t
a
nce from
ba
ttery (power
s
o
u
rce) to C
u
ddy dc
u
nit
Tot
a
l length of
b
oth po
s
itive
a
nd
neg
a
tive wire
s
a
dded together
Wire
S
ize
AWG
5 ft
a
nd
u
nder (1.5m
a
nd
u
nder)
10 ft
a
nd
u
nder (
3
.0m
a
nd
u
nder)
#6
5 ft to 7.5 ft (1.5m to 2.
3
m)
10 ft to 15 ft (
3
.0m to 4.6m)
#6
7.5 ft to 10 ft (2.
3
m to
3
.0m)
15 ft to 20 ft (4.6m to 6.1m)
#4
10 ft to 12.5 ft (
3
.0m to
3
.
8
m)
20 ft to 25 ft (6.1m to 7.6m)
#4
12.5 ft to 15 ft (
3
.
8
m to 4.6m)
25 ft to
3
0 ft (7.6m to
9
.1m)
#2
15 ft to 20 ft (4.6m to 6.1m)
3
0 ft to 40 ft (
9
.1m to 12.2m)
#2
20 ft to 25 ft (6.1m to 7.6m)
40 ft to 50 ft (12.2m to 15.2m)
#1
25 ft to
3
0 ft (7.6m to
9
.1m)
50 ft to 60 ft (15.2m to 1
8
.
3
m)
#0
DC Wire
S
ize Table*
* T
ab
le derived from ABYC
s
ection E
9
, t
ab
le
9
for 12 VDC
s
y
s
tem
s
. The
s
e
s
pecific
a
tion
s
were c
a
lc
u
l
a
ted
us
ing
3%
volt
a
ge drop
a
nd
a
m
a
xim
u
m c
u
rrent dr
a
w of 50
a
mp
s
for C
u
ddy dc
a
ir conditioner
a
nd
p
u
mp.
Fig. 15 - DC Wire Sizing Table
Summary of Contents for Cuddy dc
Page 2: ......
Page 22: ...22 English L 2028 Fig 8 Wiring Diagram of ZF3 5 ...
Page 24: ...24 English L 2028 Fig 11 Wiring Diagram for Cuddy dc CD3 5HV 12VDC ...
Page 34: ......
Page 35: ......