6 TECHNICAL  SPECIFICATIONS

Product Models

Forensic ComboDock (Model: FCDv5.5)

U.S. Patent No.

8,090,904

Drive Interface Types & 

Speeds

PATA/IDE: up to 133 MB/s

SATA (with eSATA cable): up to 6 Gbps                           

Host Interface Types & 

Speeds

eSATA: up to 6 Gbps

USB 3.0: up to 5 Gbps

FireWire 800: up to 800 Mbps

USB Micro-B: up to 480 Mbps (Admin configuration only)

Drive Types Supported

2.5” and 3.5” rotational and solid state SATA drives

3.5” rotational IDE/PATA drives

2.5” rotational IDE/PATA drives*, Hitachi 1.8” drives*, Toshiba 1.8” drives*, MacBook Air 2010*, 

MacBook Air 2011*, mSATA*, mini PCIe PATA*, mini PCIe SATA*, mini PCIe USB*

*Requires the appropriate CRU SATA or PATA adapter

Host Data Connectors

One (1) USB 3.0 connector (backwards compatible with USB 2.0)

One (1) eSATA connector

Two (2) FireWire 800 connectors

Supported Operating 

Systems

Windows 10, 8, 7, and Vista

Windows Server 2012 and 2008 product families

Mac OS X 10.4.x or higher (USB 3 requires 10.8 or later)

Linux distributions that support the connection type used    

Compliance

EMI Standard: FCC Part 15 Class A, CE

EMC Standard: EN55022, EN55024

RCM

Product Weight

0.4 pounds (0.18 kg)

Product Dimensions

2.95” x 4.33” x 1.06” (75mm x 110mm x 27mm)

Technical Support

Your investment in CRU products is backed up by our free technical support for the lifetime of the 

product. Contact us through our website, 

cru-inc.com/support

 or call us at 1-800-260-9800 or +1-360-

816-1800. 

© 2015, 2017 CRU Acquisition Group, LLC. ALL RIGHTS RESERVED. 

This User Manual contains proprietary content of CRU Acquisition Group, LLC (“CRU”) which is protected by copyright, trademark, and other intellectual property rights.

Use of this User Manual is governed by a license granted exclusively by CRU (the “License”). Thus, except as otherwise expressly permitted by that License, no part of 

this User Manual may be reproduced (by photocopying or otherwise), transmitted, stored (in a database, retrieval system, or otherwise), or otherwise used through any 

means without the prior express written permission of CRU.

Use of the full Forensic ComboDock product is subject to all of the terms and conditions of this User Manual and the above referenced License. 

CRU

®

 and WiebeTech

®

 (collectively, the “Trademarks”) are trademarks owned by CRU and are protected under trademark law. This User Manual does not grant any user 

of this document any right to use any of the Trademarks. 

Product Warranty

CRU warrants this product to be free of significant defects in material and workmanship for a period of two years from the original date of purchase. CRU’s warranty is 

nontransferable and is limited to the original purchaser.

Limitation of Liability

The warranties set forth in this agreement replace all other warranties. CRU expressly disclaims all other warranties, including but not limited to, the implied warranties 

of merchantability and fitness for a particular purpose and non-infringement of third-party rights with respect to the documentation and hardware. No CRU dealer, agent, 

or employee is authorized to make any modification, extension, or addition to this warranty. In no event will CRU or its suppliers be liable for any costs of procurement 

of substitute products or services, lost profits, loss of information or data, computer malfunction, or any other special, indirect, consequential, or incidental damages 

arising in any way out of the sale of, use of, or inability to use any CRU product or service, even if CRU has been advised of the possibility of such damages. In no case 

shall CRU’s liability exceed the actual money paid for the products at issue. CRU reserves the right to make modifications and additions to this product without notice 

or taking on additional liability.

FCC Compliance Statement: 

“This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.” 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can 

radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Opera-

tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense.

In the event that you experience Radio Frequency Interference, you should take the following steps to resolve the problem: 

1) 

Ensure that the case of your attached drive is grounded. 

2) 

Use a data cable with RFI reducing ferrites on each end. 

3) 

Use a power supply with an RFI reducing ferrite approximately 5 inches from the DC plug.

4) 

Reorient or relocate the receiving antenna.

Part Number: A9-000-0056 Rev 1.2

FOR OFFICE OR COMMERCIAL USE

1000 SE Tech Center Drive, Suite 160, Vancouver, WA 98683

Summary of Contents for WiebeTech Forensic ComboDock

Page 1: ...ion Four separate host attachment options USB 3 0 USB 2 0 FireWire 800 and eSATA for compatibility with virtually any computer Multiple LEDs indicate operational status including disk activity hidden area detection error state and the status of power input and output LCD menu allows user to configure settings and view information on attached drives Able to detect and create hidden areas HPAs or DC...

Page 2: ...owing list contains the items that are included in the complete configuration for this device Please contact CRU if any items are missing or damaged Accessories Quantity Forensic ComboDock 1 AC adapter and power cord 1 USB 3 0 cable 1 FireWire 800 cable 1 eSATA cable 1 SATA drive attachment cable 1 IDE cable 1 Molex Mini Fit to legacy power cable 1 Metal drive plate 1 Packet of screws and bumpers ...

Page 3: ...he included AC adapter or a SATA power cable from the inside of your computer case g Turn on the power switch h The Select Mode screen will display on the top LCD panel Press the Up or Down buttons to select between write blocked or read write modes and then press Enter Write blocked will always be the default mode You are now ready to use the Forensic ComboDock to access the drive If the hard dri...

Page 4: ...health Displays the S M A R T status of the attached drive Start Stops Displays how many times the attached drive has spun up and spun down Power cycles Displays how many power on off cycles the attached drive has undergone Bad sectors Displays the number of bad sectors reported by the attached drive View Dock Info Product Name Displays the brand name of the product e g Forensic ComboDock Unique I...

Page 5: ...tion Download it here www cru inc com support software downloads configurator software download Setup Instructions Connect the the provided USB micro B cable to the Admin port on the Forensic ComboDock and connect the other end to your computer Then turn on the Forensic ComboDock Finally open the Configurator application If your product is running outdated firmware you will see a prompt asking you...

Page 6: ...ignificant defects in material and workmanship for a period of two years from the original date of purchase CRU s warranty is nontransferable and is limited to the original purchaser Limitation of Liability The warranties set forth in this agreement replace all other warranties CRU expressly disclaims all other warranties including but not limited to the implied warranties of merchantability and f...