Operation

Connecting the SCSI ID Selector Switch

NOTE

: The SCSI ID selector switch is not required. The SCSI 

ID can be set by with the hard drive jumpers.  Refer to hard 

drive documentation for details.

The CRU DataPort 5, 5+ and 6 SCSI carriers have a SCSI ID selec-

tor dial switch which allows the user to externally set the drive 

SCSI ID number.  The selector switch is connected to the SCSI ID 

selector header on the drive by a BCD cable.  To connect the BCD 

cable use the following directions.

1.  Locate the SCSI ID selector header on the hard drive and re-

move the jumpers.  Refer to the drive documentation to locate 

the SCSI ID selector header.

2.  For narrow SCSI devices see diagram 1.  For 68-pin wide SCSI 

devices seen diagram 2.

 

 

 

DataPort 5, 5+ and 6 LED Functions

The green LED on the DataPort 5 and 5+ will light up when the 

DataPort is locked and powered up.  The green LED will blink 

when the fan is not functioning.  The red LED is the drive activity 

LED and will flash when there is drive activity.

Fan Alarm

The DataPort 5+ and 6 have a fan alarm that will sound if the 

fan no longer functions properly.  The alarm can be silenced by 

removing the jumper between the fan and the alarm on the back 

of the DataPort frame.  Save the jumper and re-install it after re-

placing the fan.  Please contact CRU to obtain a replacement fan.

Product Warranty 

CRU-DataPort (CRU) warrants the DataPort 5 and 5+ and 6 to 

be free of significant defects in material and workmanship for a 

period of five (5) years from the original date of purchase. CRU’s 

warranty is nontransferable and is limited to the original pur-

chaser. 

Limitation of Liability 

The warranties set forth in this agreement replace all other war-

ranties. CRU expressly disclaims all other warranties, including 

but not limited to, the implied warranties of merchantability and 

fitness for a particular purpose and noninfringement of third-party 

rights with respect to the documentation and hardware. No CRU 

dealer, agent or employee is authorized to make any modification, 

extension, or addition to this warranty. In no event will CRU or 

its suppliers be liable for any costs of procurement of substitute 

products or services, lost profits, loss of information or data, com-

puter malfunction, or any other special, indirect, consequential, 

or incidental damages arising in any way out of the sale of, use 

of, or inability to use any CRU product or service, even if CRU has 

been advised of the possibility of such damages. In no case shall 

CRU’s liability exceed the actual money paid for the products at 

issue. CRU reserves the right to make modifications and additions 

to this product without notice or taking on additional liability.    

 

     

Register your product at www.CRU-DataPort.com 

A5-002-0001 Rev. 2.0

Diagram 2

 

 

 

Diagram 1 

 

Reviews: