Operation
Connecting the SCSI ID Selector Switch
NOTE
: The SCSI ID selector switch is not required. The SCSI
ID can be set by with the hard drive jumpers. Refer to hard
drive documentation for details.
The CRU DataPort 5, 5+ and 6 SCSI carriers have a SCSI ID selec-
tor dial switch which allows the user to externally set the drive
SCSI ID number. The selector switch is connected to the SCSI ID
selector header on the drive by a BCD cable. To connect the BCD
cable use the following directions.
1. Locate the SCSI ID selector header on the hard drive and re-
move the jumpers. Refer to the drive documentation to locate
the SCSI ID selector header.
2. For narrow SCSI devices see diagram 1. For 68-pin wide SCSI
devices seen diagram 2.
DataPort 5, 5+ and 6 LED Functions
The green LED on the DataPort 5 and 5+ will light up when the
DataPort is locked and powered up. The green LED will blink
when the fan is not functioning. The red LED is the drive activity
LED and will flash when there is drive activity.
Fan Alarm
The DataPort 5+ and 6 have a fan alarm that will sound if the
fan no longer functions properly. The alarm can be silenced by
removing the jumper between the fan and the alarm on the back
of the DataPort frame. Save the jumper and re-install it after re-
placing the fan. Please contact CRU to obtain a replacement fan.
Product Warranty
CRU-DataPort (CRU) warrants the DataPort 5 and 5+ and 6 to
be free of significant defects in material and workmanship for a
period of five (5) years from the original date of purchase. CRU’s
warranty is nontransferable and is limited to the original pur-
chaser.
Limitation of Liability
The warranties set forth in this agreement replace all other war-
ranties. CRU expressly disclaims all other warranties, including
but not limited to, the implied warranties of merchantability and
fitness for a particular purpose and noninfringement of third-party
rights with respect to the documentation and hardware. No CRU
dealer, agent or employee is authorized to make any modification,
extension, or addition to this warranty. In no event will CRU or
its suppliers be liable for any costs of procurement of substitute
products or services, lost profits, loss of information or data, com-
puter malfunction, or any other special, indirect, consequential,
or incidental damages arising in any way out of the sale of, use
of, or inability to use any CRU product or service, even if CRU has
been advised of the possibility of such damages. In no case shall
CRU’s liability exceed the actual money paid for the products at
issue. CRU reserves the right to make modifications and additions
to this product without notice or taking on additional liability.
Register your product at www.CRU-DataPort.com
A5-002-0001 Rev. 2.0
Diagram 2
Diagram 1