background image

Product Warranty 

CRU-DataPort (CRU) warrants the Data Express DE100 to be free of 

significant defects in material and workmanship for a period of five 

years from the original date of purchase. CRU’s warranty is nontrans-

ferable and is limited to the original purchaser.

Limitation of Liability

The  warranties  set  forth  in  this  agreement  replace  all  other  warran-

ties.  CRU  expressly  disclaims  all  other  warranties,  including  but  not 

limited to, the implied warranties of merchantability and fitness for a 

particular purpose and non-infringement of third-party rights with re-

spect  to  the  documentation  and  hardware.  No  CRU  dealer,  agent  or 

employee is authorized to make any modification, extension, or addi-

tion to this warranty. In no event will CRU or its suppliers be liable for 

any costs of procurement of substitute products or services, lost profits, 

loss  of  information  or  data,  computer  malfunction,  or  any  other  spe-

cial, indirect, consequential, or incidental damages arising in any way 

out of the sale of, use of, or inability to use any CRU product or ser-

vice, even if CRU has been advised of the possibility of such damages. 

In no case shall CRU’s liability exceed the actual money paid for the 

products  at issue. CRU reserves the right to make modifications and 

additions to this product without notice or taking on additional liability. 

Certification

EMI Standard:   FCC Part 15 Class B, CE

EMC Standard:   EN55022, EN55024

FCC Certification

This device has been tested and found to comply with the limits 

for a Class B digital device, pursuant to Part 15 of the FCC rules. 

Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received;      

 

including interference that may cause undesired operation.

Register your product at www.CRU-DataPort.com and be 

automatically entered to win a free prize!

 

      A7-100-0004  Rev. 1.0

Rugged, Reliable, Mobile, Secure

TM

1-800-260-9800

www.CRU-DataPort.com

DataPort

Selecting the Unit ID Number:

 Use the alignment tool (provided) 

to select the ID number of the disk drive.

NOTE: 

The lock on the Data Express receiving frame functions 

as a lock and a DC power switch for the carrier unit. The lock 

MUST be engaged (turned counterclockwise) in order to supply 

power to the carrier and installed drive unit.

Figure 3: Typical SCSI ID Select Connections ( 2mm drive pins)

Drive Carrier

ID Select 

Switch

Drive Carrier 

Guide

Receiving 

Frame

Unit ID 

Number 

Display

Lock and 

DC Power 

Switch

Front of Unit

Drive Carrier 

(removed)

Figure 4: Unit ID Select Switch Location

Reviews: