background image

Rugged, Reliable, Mobile, Secure

TM

1-800-260-9800

www.CRU-DataPort.com

Fan Error LED Disable Button

 

This button allows the user to disable the Fan Error LED (insert a paper 

clip or similar object to disable). CRU-DataPort recommends replacing 

a faulty fan immediately. Contact CRU-DataPort for spare fan ordering 

information.

Drive Activity LED Pins

Pin 1 can be used for host connection (cable not included) to the Drive 

Activity LED (Figure 2) if your drive does not support this feature (refer to 

your SAS PC system/host controller manufacturer’s documentation for 

further information). For Host Activity LED support instead of Drive Activ-

ity LED support remove the HDD activity LED disable jumper.

Cooling Fan

Field-replaceable fan provides ample cooling (4.6 CFM) for drive.

Installation

NOTE:

  A #1 and #2 Phillips screwdriver will be required during    

       this procedure.

1. Remove the drive cover from the DX115 drive carrier and save the screws.

2.  Carefully insert the drive (not included) into the carrier. Slide the drive 

towards the Drive Carrier Board, so that the I/O connector on the 

drive mates with the connector on the Drive Carrier Board (Figure 3). 

Turn the drive/carrier assembly over.

3.  Fasten the drive into place using the mounting screws provided 

(Figure 3). Some drives may require minor adjustment before securing 

into carrier with screws.

4. Install the provided drive cover.

Limited Product Warranty 

CRU-DataPort (CRU) warrants the Data Express DX115 DC to be free 

of significant defects in material and workmanship for a period of five 

years from the original date of purchase. CRU’s warranty is nontransfer-

able and is limited to the original purchaser.

Limitation of Liability

The warranties set forth in this agreement replace all other warranties. CRU 

expressly disclaims all other warranties, including but not limited to, the 

implied warranties of merchantability and fitness for a particular purpose 

and non-infringement of third-party rights with respect to the documen-

tation and hardware. No CRU dealer, agent or employee is authorized to 

make any modification, extension, or addition to this warranty. In no event 

will CRU or its suppliers be liable for any costs of procurement of substi-

tute products or services, lost profits, loss of information or data, computer 

malfunction,  or  any  other  special,  indirect,  consequential,  or  incidental 

damages arising in any way out of the sale of, use of, or inability to use 

any CRU product or service, even if CRU has been advised of the possibility 

of such damages. In no case shall CRU’s liability exceed the actual money 

paid for the products at issue. CRU reserves the right to make modifications 

and additions to this product without notice or taking on additional liability

Certification

EMI Standard: 

FCC Part 15 Class B, CE CISPR B

EMC Standard: 

EN55022, EN55024

This device has been tested and found to comply with the limits for a 

Class B digital device, pursuant to Part 15 of the FCC rules. Operation is 

subject to the following two conditions:

1. This device may not cause harmful interference, and
2.  This device must accept any interference received; including inter-

ference that may cause undesired operation

Register your product at www.CRU-DataPort.com

    A7-115-0003  Rev. 3.3

Figure 3 - Drive Installation

Figure 2: DX115 DC SAS Receiving Frame Rear Panel with cable 

support bracket removed (SATA receiving frame not shown) 

3.5” Bottom-mount Drive
with Four (4) #6-32
Phillips Flat Head
Screws (Provided)

Drive Carrier
Board

2.5” Bottom-mount Drive
with Four (4) #6-32
Phillips Flat Head
Screws (Provided)

Click-connect plate

GND

Host Activity 

LED Pin

Reserved 

Pins

HDD LED 

Activity Disable

Auto 

Power 

on enable

Cooling 
Fan

SAS/SATA 

Connector 

Power Connector