12
BACKGROUND FUNCTION MENU OPERATION
Press
11
【
MENU
】
for 2 seconds to enter menu list;
Turn Channel switch to select menu No.1 to No.10;
21
Press
31
【
PUSH
】
to enter the menu setup;
Turn channel switch to select wanted setup;
41
Press any other key or wait 5 seconds, the setting will be stored and exit.
51
No. Function
LCD Display
Values and Descriptions
1
Mic Gain
1-36, Total 36 levels available;
Default:
30.
2
Monitor Gain
1-32, OFF, Total 33 levels available;
Default: OFF. (Shut NOG function)
3
TOT
1-600s, OFF, Total 10minutes available;
Default:
180S. (Shut TOT function)
4
SWR
Protection
OFF:
Shut SWR function;
ON:
Open SWR function;
Default:
ON.
5
Scan Type
SQ:
SQ scan function;
TI:
Time scan function;
Default:
SQ.
6
SSB Clarifier
switch
OFF:
Shut frequency adjustment;
R:
Open RX frequency adjustment;
T:
Open TX frequency adjustment;
RT:
Open TX/RX frequency adjustment;
Default:
R.
7
Channel
Frequency
switch
CHAN:
Channel adjust;
FREQ:
Frequency adjust;
Default:
FREQ.
8
ASQ Control
01~09:
Total 9 Levels;
Default:
05.
9
Offset
frequency
Frequency range:
100Hz~5MHz;
Default:
100KHz.
10
Reset
OPT:
All function setup resume default;
ALL:
All channels and setup resume default;
Default:
OPT.
Summary of Contents for SS 7900
Page 1: ......
Page 2: ...USER MANUAL 10 Meter Amateur Radio CopyrightCRT France 2015 ...
Page 3: ......
Page 4: ...and EN 62311 ...
Page 5: ......