Can I use more than one wireless iOS controller? 

Yes, but performance might be negatively impacted. 

Crown has verified performance to be acceptable with 2x iOS controllers running on the same USBX 

server. 

How many amplifiers can I connect to the USB port on USBX?  

Up to 8.

 

Can I hook multiple units together via wired Ethernet?  

Yes. Each USBX can serve up to 8 amplifiers, 

then multiple USBX units can be connected to an Ethernet router.

 

Can I connect to other amps wirelessly through the USBX?  

No.  USBX is designed as a server, not a 

wireless access point. 

How do I configure the wireless SSID and PW and other network settings?  

This is generally for 

advanced users but there are settings in Powered by Crown and in Audio Architect which allow 

adjustment of all relevant network settings.

What version of Powered by Crown works with USBX?  

Version 2.0 and above. 

Can I update amplifier firmware thru USBX?  

No.

How do I set HIQNET address on the connected amplifiers?  

Amplifier HiQnet addresses can be set 

via Powered by Crown – the recommendation is to turn on and address one device at a time since 

duplicate addresses can cause communication conflicts.  HiQnet addresses can also be set via SA/AA

HiQnet addresses can also be set from the amplifier front panel on XTi/CDi/DSi:

• 

Press all three buttons

• 

Press up/next (right button) until address displayed

• 

Press set (left button) 

• 

Press up/down (right or middle buttons) to select address

• 

Press set (left button) to store the new address.  

• 

Do not power down for at least 10sec so the address can be stored. 

Summary of Contents for USBX

Page 1: ...provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www crownaudio com Trademark Notice Crown Crown Audio and Amcron are registered trademarks of Crown International Other trademarks are the property of their respective owners Later versions of this...

Page 2: ...rticularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or ...

Page 3: ... harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant t...

Page 4: ...Equipment Type Commercial Audio Power Amplifiers Family Name Crown USBX Server Model Names USBX I certify that the product identified above conforms to the requirements of the EMC Council directive 2004 108 EC and the Low Voltage Directive 2006 95 EC Issued By Harman International 1718 W Mishawaka Rd Elkhart IN 46517 U S A Date of Issue March 1 2013 Due to line current harmonics we recommend that ...

Page 5: ...A Max Size 3 75 x 2 5 x 1 9 95mm x 65mm x 48 5mm Control Supports fully featured monitoring and control of up to 8 USB enabled Crown amplifiers This includes XTi2 XTi CDi and DSi models Software Requirements For control with Apple iOS devices download the Powered by Crown application from the Apple App Store For control via HiQnet System Architect or Audio Architect see hiqnet harmanpro com to dow...

Page 6: ...B Hub USBX USB Connection USB Connection Ethernet Connection USB2 0 USB X USB Hub USBX Wifi Connection USB Connection USB Connection Small to medium Fixed Install High powered Portable Sound System For support regarding USBX and Powered by Crown please see www crownaudio com ...

Page 7: ...k broadcasting openly that s listed on the back of the USBX device 6 When prompted enter the wireless network password as it is shown on back of the USBX device The password from the factory defaults to Crown123 Ensure that DHCP is enabled in your wireless network settings to make connection as hastle free as possible 7 Close out of iOS or PC network settings and open the Powered by Crown app or H...

Page 8: ...erally for advanced users but there are settings in Powered by Crown and in Audio Architect which allow adjustment of all relevant network settings What version of Powered by Crown works with USBX Version 2 0 and above Can I update amplifier firmware thru USBX No How do I set HIQNET address on the connected amplifiers Amplifier HiQnet addresses can be set via Powered by Crown the recommendation is...

Page 9: ... What are the factory default network settings for USBX as shipped from factory Wired DHCP server required Wireless 192 168 115 1 255 255 255 0 Will BandManager work with USBX connected amps No Can I restore the USBX to factory defaults Yes USBX device settings can be configured via Powered by Crown or AA SA including Reset to Factory Defaults The unit will require full reboot to re configure all ...

Page 10: ...actical or cannot be timely made If a refund is elected then you must make the defective or malfunctioning product available to us free and clear of all liens or other encumbrances The refund will be equal to the actual purchase price not including interest insurance closing costs and other finance charges less a reasonable depreciation on the product from the date of original purchase Warranty wo...

Page 11: ...not extended by the length of time which you are deprived of the use of the new Crown product Repairs and replacement parts provided under the terms of this Crown Warranty shall carry only the unexpired portion of this Crown Warranty DESIGN CHANGES We reserve the right to change the design of any product from time to time without notice and with no obligation to make corresponding changes in produ...

Page 12: ......

Reviews: