The
Circuit Breaker Reset Buttons
(PUSH TO RESET)
are located on the back panel to protect the power sup-
plies against overload. If a circuit breaker trips, the Sig-
nal/IOC
indicator of the affected channel turns on (the
Enable indicator remains illuminated).
4.5 Filter Cleaning
Dust filters are provided on the air intakes to the cooling
system (Figure 2.1). If these filters become clogged,
the unit will not cool as efficiently as it should and may
produce lower-than-normal output levels due to high
heat diffuser temperature and activation of the
ODEP
circuitry.
To clean, remove each of the filter elements by gently
pulling them away from the front panel. Clean with mild
dishwashing detergent and warm water. Replacement
filters may be ordered from the factory.
Dust filters are not 100% efficient—depending on the
local environment, the internal heat sinks of the ampli-
fier will benefit from periodic cleaning by a qualified
technician. Internal cleaning information is available
from our Technical Support Group.