©2000 Crown International, Inc.
ODEP Voltage Chart
Tolerance ±0.1V
°C
°F
Voltage
35
95.0
10.73
34
93.2
10.66
33
91.4
10.58
32
89.6
10.51
31
87.8
10.44
30
86.0
10.37
29
84.2
10.29
28
82.4
10.22
27
80.6
10.15
26
78.8
10.07
25
77.0
10.00
24
75.2
9.93
23
73.4
9.85
22
71.6
9.78
21
69.8
9.71
20
68.0
9.64
19
66.2
9.56
18
64.4
9.49
17
62.6
9.42
16
60.8
9.34
15
59.0
9.27
5.3.4 DC Offset
Spec: 0 VDC, ±10 mV.
Procedure: Measure DC voltage at the output connec-
tors (rear panel). There is no adjustment for output off-
set. If spec is not met, there is an electrical malfunction.
Slightly out of spec measurement is usually due to U104/
U204 out of tolorance.
5.3.5 Quiescent Power Draw
Spec: 100 watts maximum
Procedure: With no input signal the amplifier should draw
no more than 100 watts from the power source. Slightly
high readings may be due to out of tolerance Output
Bias Adjustment.
5.3.6 Voltage Gain
Spec 26 dB Gain: Gain of 20.0 ±3%.
Spec 0.775V Sensitivity: ±10%.
Spec 1.4V Sensitivity: ±10%.
Procedure: No load connected. Inject a 0.775 VAC 1
kHz sine wave with the Sensitivity Switch in the 26 dB
position. Measure 15.5 VAC ±0.5 VAC at the amplifier
output. Inject a 0.775 VAC 1 kHz sine wave with the
Sensitivity Switch in the 0.775V position. Measure 64
VAC ±6 VAC at the amplifier output. Inject a 1.4 VAC 1
kHz sine wave with the Sensitivity Switch in the 1.4V
position. Measure 64 VAC ±6 VAC at the amplifier out-
put. Return the Sensitivity Switch to the 26 dB position.
5.3.7 Current Limit
Spec: 31.5 to 43.0 Amps
Procedure: Load the channel under test to 1 ohm. In-
ject a 1 kHz differentiated (10% duty cycle) square wave.
See Figure 5.1 for differentiator circuit. Increase output
level until current limit occurs. Current limit should oc-
cur between 31.5 and 43.0 amps (31.5 to 43.0 Vpk).
Observe clean (no oscillations) current clipping. See
Figure 5.2 for differentiated wave form at current limit.
In
Out
.047 uF
1K Ohm
Figure 5.1 Differentiator Circuit
Figure 5.2 Differentiated wave form at current limit
Summary of Contents for Macro-Tech 2402
Page 41: ...Module Parts 9 3 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 42: ...MA 2402 Service Manual 9 4 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 43: ...Module Parts 9 5 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 44: ...MA 2402 Service Manual 9 6 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 47: ...Module Parts 9 9 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 48: ...MA 2402 Service Manual 9 10 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 51: ...Module Parts 9 13 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 52: ...MA 2402 Service Manual 9 14 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 53: ...Module Parts 9 15 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 55: ...Module Parts 9 17 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 56: ...MA 2402 Service Manual 9 18 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 57: ...Module Parts 9 19 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 59: ...Module Parts 9 21 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 60: ...MA 2402 Service Manual 9 22 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 61: ...Module Parts 9 23 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 62: ...MA 2402 Service Manual 9 24 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 63: ...Module Parts 9 25 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 64: ...MA 2402 Service Manual 9 26 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 65: ...Module Parts 9 27 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 66: ...MA 2402 Service Manual 9 28 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 67: ...Module Parts 9 29 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 68: ...MA 2402 Service Manual 9 30 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 69: ...Module Parts 9 31 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 70: ...MA 2402 Service Manual 9 32 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 71: ...Module Parts 9 33 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 72: ...MA 2402 Service Manual 9 34 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 73: ...Module Parts 9 35 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 74: ...MA 2402 Service Manual 9 36 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 77: ...Module Parts 9 39 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 78: ...MA 2402 Service Manual 9 40 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 79: ...Module Parts 9 41 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 81: ...Module Parts 9 43 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 82: ...MA 2402 Service Manual 9 44 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 83: ...Module Parts 9 45 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 85: ...Module Parts 9 47 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...
Page 86: ...MA 2402 Service Manual 9 48 Module Parts 130445 1 Rev A 2000 Crown International Inc ...
Page 87: ...Module Parts 9 49 130445 1 Rev A MA 2402 Service Manual 2000 Crown International Inc ...