background image

M

ANUAL 10094 

R

EV 0 (04/21)

$21.00

GAS SKILLETS

M

ANUAL 

S

ECTION 

CO

 

IMPORTANT FOR FUTURE REFERENCE 

Please complete this information and retain this 

manual for the life of the equipment:

 

Model #:  ___________________________ 
Serial #:  ___________________________ 
Date Purchased: _____________________ 

 

 

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury 

or death. Read the installation, operating and maintenance instructions thoroughly before installing or 

servicing this equipment.

Model GMTS-60

CROWN FOOD SERVICE EQUIPMENT

 

 A Middleby Company

70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9

Telephone: 919-762-1000               www.crownsteamgroup.com

Gas Skillets 

GMTS-30, GMTS-40 & GMTS-60

Installation & Operation Manual

Summary of Contents for GMTS-30

Page 1: ...________ WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly be...

Page 2: ...al should be retained for future reference NOTICE This product is intended for commercial use only NOT FOR HOUSEHOLD USE Copyright 2021 by Crown All rights reserved Published in the United States of A...

Page 3: ...ANUAL FOR FUTURE REFERENCE Table of Contents Important Notes For Installation and Operation 2 Service Connections 4 Installation Instructions 6 Operating Instructions 8 Cleaning 10 Cooking Guidelines...

Page 4: ...k 6 152 mm 33 25 845 40 50 1029 3 75 95 2 38 60 D B E C SERVICE CONNECTIONS ELECTRICAL CONNECTIONS Unless otherwise specified Field Wire Electrical Connection to be 120 Volts 60 Hz single phase with g...

Page 5: ...single phase with grounding wire 10 Amp minimum supply GAS CONNECTION 3 4 IPS A gas shut off valve is installed in supply piping COLD WATER 3 8 O D tubing to faucet OPTIONAL HOT WATER 3 8 O D tubing t...

Page 6: ...accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as applicable Ventilation must be provided in acc...

Page 7: ...n open flame to check for gas leaks Check all connections for leaks using soapy water before use CAUTION The pipe thread compound used when installing pipes must be a type that is resistant to the act...

Page 8: ...eating GREEN IGNITION LIGHT Will light when ignition has occurred RED TEMPERATURE LIGHT Will light when heating elements are supplying heat to the tilting braising pan THERMOSTAT When turned on will i...

Page 9: ...d hold TILT SWITCH in the UP mode until desired pan position has been reached The braising pan will empty when raised to the top tilt position When the braising pan is raised 5 or more the gas supply...

Page 10: ...uring spout lid and exterior surfaces with mild detergent and warm water If necessary soak pan to remove food that is stuck to pan surface Rinse thoroughly and wipe dry with a soft clean cloth 2 Clean...

Page 11: ...ANUAL 10094 REV 0 08 21 PAGE 11 OF24 Gas Skillets Cooking Guidelines Cooking Method Temperature F Thermostat Setting Simmering 200 Maximum 1 4 Saut ing 225 275 5 6 Searing 300 350 7 8 Frying 325 375 8...

Page 12: ...ory and no further adjustment should be needed If the unit fails to operate properly all service work must be performed by a qualified service agent 1 Hot oil in the Hydraulic System is one of the pri...

Page 13: ...ed above When adjustment is complete replace the hexagon cover This will seal the relief valve area The actual factory set pressure is noted on the label and should not be exceeded as this affects the...

Page 14: ...Wrong gas supply 4 Incorrect pressure at supply Braising Pan Will Not Operate Up or Down 1 Motor power supply not ON 2 Defective UP DOWN switch 3 SEE TROUBLESHOOTING HYDRAULICS Troubleshooting Hydrau...

Page 15: ...Check for vacuum leaks in suction line 2 Vacuum leak at pump shaft seal 3 Check alignment with drive mechanism Misalignment will cause wear and subsequent high noise level operation 4 Relief valve se...

Page 16: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 16 OF 24 Gas Skillets Material Safety Data Sheets...

Page 17: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 17 OF24 Gas Skillets Material Safety Data Sheets...

Page 18: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 18 OF 24 Gas Skillets Material Safety Data Sheets...

Page 19: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 19 OF24 Gas Skillets Material Safety Data Sheets...

Page 20: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 20 OF 24 Gas Skillets Material Safety Data Sheets...

Page 21: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 21 OF24 Gas Skillets Material Safety Data Sheets...

Page 22: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 22 OF 24 Gas Skillets Material Safety Data Sheets...

Page 23: ...INSTALLATION OPERATION MANUAL 10094 REV 0 08 21 PAGE 23 OF24 Gas Skillets Material Safety Data Sheets...

Page 24: ...ement parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Crown Authorized Service Agency or your dealer To avoid co...

Reviews: