Power Base-3 & 1400CSL Amplifier Service Manual
7
Voltage Conversion
Note: The only versions of this
product produced at the Crown
Factory with international volt-
age capabilities are the CSL
versions built specifically for
sale outside the United States.
P16
P10
P15
P14
P13
P12
P11
P9
P8
P7
P6
P5
P4
P3
P2
P1
P22
P21
P18
P17
P19
P20
F1
F100
BRN
BLU
100V Connections:
P10 to P15
P11 to P14
P7 to P12
120V Connections:
P10 to P16
P11 to P14
P7 to P13
220V Connections:
P10 to P15
P9 to P14
P8 to P13
240V Connections:
P10 to P16
P9 to P14
P8 to P13
For list of applicable
transformer, fuse F100,
fanformer, and power
cord refer to voltage-
parts cross-reference.
S1 Power Switch
PB/CSL Universal Fuse Board
Specific parts are required for the PB-3/1400CSL in
order to be used at different international line volt-
ages. Refer also to Mechanical Parts Lists.
Voltage Specific Parts:
30A Breaker for 100-120V Operation
C 9837-3
15A Breaker for 220-240V Operation
C 9839-9
0.5A F1, Low Voltage*
A10285-7
Power Transformer (United States)
D 8598-1
Power Transformer (Universal)
D 8601-3
Transmotor 120V 60 Hz Only
H43065-4
Transmotor 120V 50-60 Hz
H43055-5
*Use 0.3A for UL
®
approval
A10285-33