INSTALLATION AND OPERATION MANUAL, ELECTRIC SELF GENERATING SINGLE AND
TWIN STEAM MIXER KETTLE, MODELS ELTM-40 TO 100 AND ELTM 40-2 TO 100-2
Part No. 10041R4
22
2018-08-08
6.0 MAINTENANCE
(Continued)
B. SETTING THE MIXER SYSTEM FLOW
1.
On the operator panel, switch “POWER” to on, “MIXER” to on, and set mixer
speed to “FAST”, the maximum speed.
2. Increase or decrease flow to maximum rpm as listed, or less if requested by
customer. Turn in “C” to decrease, turn out to increase.
40 gallon kettle
60 gallon kettle
80 gallon kettle
100 gallon kettle
54 RPM
48 RPM
43 RPM
40 RPM
CAUTION: Do not exceed 54 rpm! Decreasing the flow to less than 10
rpm may over centre the swash plate and will damage the pump!
3. Use jam nut to lock adjusting screw when complete.
C. SETTING THE BRIDGE ACTUATOR
1.
On the operator panel, switch “POWER” to on, “MIXER” to on, and set mixer
speed to “STOP”.
2. The pressure reducing valve and associated gauge are located at the back of
the hydraulic unit. Adjust it to 800 psi.
3. The speed of the actuator is controlled by an in-line flow control valve also located at
the back of the unit. There is also a locking set screw provided on the adjusting knob.
4.
Using the “RAISE/LOWER” tilt switch on the operator panel, adjust the flow
control so that the stroke is completed at a safe speed.