TALON SERIES 

TLC-S 

PROFESSIONAL

 

PASSIVE INFRARED &  

MICROWAVE DETECTOR 

 

                            

 

 

     

 

      

          ELECTRONIC ENGINEERING LTD. 

INSTALLATION INSTRUCTIONS 

P/N: 7151288 REV.B   A.Y. 

 

TLC-S FEATURES 

A new generation of professional movement 

spread spectrum analyzing PIR & MW 

detectors. 

  Dual element PYRO sensor and hard lens for 

outstanding detection performance and 

elimination of false alarms. 

  Microwave detection based on Doppler concept. 
  Unique Microwave Motion Sensor Module with 

microstrip patch antenna. 

  VLSI based electronics with movement speed 

spectrum analysis. 

  AND & OR alarm signal selection.  
  Height installation calibrations free. 
  User-friendly installation with or w/o swivel 

bracket. 

  2-way Microwave sensitivity adjustment. 
  2-way PIR sensitivity adjustment. 

  BI directional temperature compensation. 
  Environmental immunity. 

 

 

The TLC-S is a combination of PIR & MW 

detectors, providing protection from intruders by 

PYRO sensor element and MW (based on Doppler 

concept).  

Using micro controller for PIR & MW signal 

analyzing, with special ASIC technology for PIR 

pulse processing, assure “false alarm free” 

operation. 

MOUNTING THE DETECTOR

 

Choose a location most likely to intercept an 

intruder. (Our recommendation is a corner 

installation). See detection pattern in Fig.: 5, 6. 

The dual-element high quality sensor detects 

motion crossing the beam; it is slightly less 

sensitive detecting motion toward the detector. 

The TLC-S performs best when provided with a 

constant and stable environment. 

NOTE

: recommended installation height is 2.4m 

(option: 1.5m to 3.0m). 

 

4

 

 

5

 

 

6

 

AVOID THE FOLLOWING LOCATIONS 

  Facing direct sunlight. 
  Facing areas subject to rapid quick 

temperature changes. 

  Areas with air ducts or substantial air flows. 
  Facing metal doors. 

 
WIRE SIZE REQUIREMENTS 

Use the following table to determine required 

wire gauge and length. 

Wire Diameter  mm   .5       .75      1.0       1.5 

Wire Gauge:     #       22       20       18        16 

Wire Length:     m     205     310     510      870 

                       

Ft.    800    1200   2000    3400 

 

 

 

FIG. 1 - REMOVAL OF FRONT COVER 

 

 

1.  To remove the front cover, insert a flat 

screwdriver in the slot between the front and 

the bottom above the holding screw hole and 

push gently, until the front cover is 

disengaged and the opening click is 

heard.(Fig. 1) 

2.   Remove the PC board (unscrew holding 

screw)  

3.  Break out the desired holes for proper wiring 

as per fig. 2. 

4.   Insert the wire through the wire access hole, 

and mount the detector base to the wall, 

corner or ceiling with the necessary number 

of screws and the suitable bracket. 

5.   Reinstall the PC board. 

6.   Access for wiring connections is easy via the 

terminal block located on the PCB. See fig. 3. 

7.   Replace the cover by inserting it back in the 

appropriate closing pin until the closing click 

is heard. 

 

7

 

 

8

 

 

9

 

FIG. 2 - KNOCKOUT HOLES 

 

 

FIG. 3 - 

TERMINAL BLOCK 

 CONNECTIONS 

 

 
Terminal 1 – Marked “ - ” ( GND ) 

Connect to ground of the control unit. 

Terminal 2 – Marked “ + ” ( +12V ) 

Connect to a positive Voltage output of 8.2 -16Vdc 

source (usually from the alarm control unit) 

Terminals 3 & 4 - Marked “ RELAY ” 

These are the output relays contacts of the 

detector. Connect to a normally closed zone in the 

control unit. 

Terminals 5 & 6 - Marked “ TAMPER ”  

If a Tamper function is required connect these 

Terminals to a 24-hour normally closed protective 

zone in the control unit. If the front cover of the 

detector is opened, an immediate alarm signal will 

be sent to the control unit. 

  

 

FIG. 4 - PCB LAYOUT 

 

 

 

10

 

 

11

 

 

12

 

MW SENSITIVITY ADJUSTMENT  

 

JUMPER “JP1” 

provides sensitivity control of 

MW (DOPPLER) according to the environment. 

Position Up – “H” – High sensitivity  

For normal operation – immediately detection. 

Position Down – “L” – Low sensitivity 

For harsh environments.  

POTENTIOMETER “RV1” – adjusts the 

detection pattern scale between 30% and 

100% (factory set to 70%). Rotate the 

potentiometer clockwise to increase pattern 

scale.  

Rotate the potentiometer counter-clockwise to 

decrease pattern scale. 

The potentiometer at min. “ – “ is equivalent to a 

distance of 6m - 8m.

 

Dimension change according to installation 

location and room size 

 

 

 PIR SENSITIVITY ADJUSTMENT 

 

JUMPER “JP4” - provides sensitivity control of 

PIR according to the environment.  

Position Up – “H” – High sensitivity  

For stable environments. 

Position Down – “L” – Low sensitivity  

For harsh environments.  

 

POTENTIOMETER “RV2” – adjustment 

according to protected area range. 

Use RV2 to adjust the detection range between 

68% and 100% (factory set to 84%). Rotate the 

potentiometer clockwise to increase range, 

counter-clockwise to decrease range. 

 

 

 

 

 

 

 

ALARM MODE SETTING  

JUMPER “JP2” OR - AND  

Position Left “OR”   

The alarm signal (relays activation) occurred 

when one of the sensor’s signals - PIR 

OR

 MW - 

is present.  

The effective detection range is the range of the 

PIR pattern 

OR

 MW pattern correspondently. 

Position Right “AND”  

The alarm signal occurred only when both 

sensors (PIR 

AND

 MW) are present at the same 

time.  

The effective detection range is the range of which 

the PIR patterns 

AND

 MW lobe are intersected. 

 

 

 

You must reset the detector from 

Control Panel before the new 

settings will take effect.

 

A.   Wire access 

holes  

B.   Use for flat 

wall mounting 

C.   Corner 

mounting - use 

all 4 holes. 

Sharp left or 

right angle 

mounting - use 

2 holes (top 

and bottom) 

D.   For bracket 

mounting

 

      -            +           RELAY           TAMPER

 

1       2       3       4        5      6

 

 

! "

# $

% &

!

'

!

$

! "

#

After adjusting the sensitivity perform a 

walk test to verify optimum correct 

sensitivity in the protected area.