SRDT-15 

PROFESSIONAL

 

PASSIVE INFRARED &  

MICROWAVE DETECTOR 

 

                            

 

 

ELECTRONIC ENGINEERING LTD. 

INSTALLATION INSTRUCTIONS 

P/N: 7121287 REV.D   A.Y. 

 

SRDT-15 FEATURES 

A new generation of professional 
movement spread spectrum analyzing PIR 
& MW detectors. 

  Dual element PYRO sensor and hard lens for 

outstanding detection performance and 
elimination of false alarms. 

  Microwave detection based on Doppler concept. 

  Unique Microwave Motion Sensor Module with 

microstrip patch antenna. 

  VLSI based electronics with movement speed 

spectrum analysis. 

  AND & OR alarm signal selection.  

  Height installation calibrations free. 

  User-friendly installation with or w/o swivel 

bracket. 

  2-way Microwave sensitivity adjustment. 

  2-way PIR sensitivity adjustment. 

  BI directional temperature compensation. 

  Environmental immunity. 

 

 

The SRDT-15 is a combination of PIR & MW 
detectors, providing protection from intruders by 
PYRO sensor element and MW (based on Doppler 
concept).  
Using micro controller for PIR & MW signal 
analyzing, with special ASIC technology for PIR 
pulse processing, assure “false alarm free” 
operation. 

MOUNTING THE DETECTOR

 

Choose a location most likely to intercept an 
intruder. (Our recommendation is a corner 
installation). See detection pattern in Fig.: 5, 6. 
The dual-element high quality sensor detects 
motion crossing the beam; it is slightly less 
sensitive detecting motion toward the detector. 
The SRDT-15 performs best when provided with 
a constant and stable environment. 

NOTE

: recommended installation height is 2.1m 

(option: 1.5m to 3.0m). 

 

4

 

 

5

 

 

6

 

AVOID THE FOLLOWING LOCATIONS

 

  Facing direct sunlight. 

  Facing areas subject to rapid quick 

temperature changes. 

  Areas with air ducts or substantial air 

flows. 

  Facing metal doors. 

 

WIRE SIZE REQUIREMENTS 

Use the following table to determine required wire 
gauge and length. 
Wire Diameter  mm   .5       .75      1.0       1.5 
Wire Gauge:     #       22       20       18        16 
Wire Length:     m     205     310     510      870 

                       

Ft.    800    1200   2000    3400 

 

 

FIG. 1 - REMOVAL OF FRONT COVER 

 

 

1.  To remove the front cover, insert a flat 

screwdriver in the slot between the front and 
the bottom above the holding screw hole and 
push gently, until the front cover is 
disengaged and the opening click is heard. 
(Fig. 1) 

2.  Remove the printed circuit board by spread 

out the two tabs, which are located on the 
either side of the lower half of the board. 

3.  Break out the desired holes for proper wiring.  
4.  Insert the wire through the wire access hole, 

and mount the detector base to the wall, 
corner or ceiling with the necessary number of 
screws and the suitable bracket. 

5.  Reinstall the PC board by place it on the lower 

stoppers and push the PCB toward the 
bottom cover. 

6.  Access for wiring connections is easy via the 

terminal block located on the PCB. (Fig. 3) 

7.  Replace the cover by inserting it back in the 

appropriate closing pin until the closing click is 
heard. 

 

7

 

 

8

 

 

9

 

FIG. 2 - KNOCKOUT HOLES 

C

B

A

D

C

A

B

B

B

B

B

B

B

C

C

D

C

C

 

 

FIG. 3 - 

TERMINAL BLOCK 

 CONNECTIONS 

 

 

Terminal 1 – Marked “ - ” ( GND ) 

Connect to  ground of the control unit. 

Terminal 2 – Marked “ + ” ( +12V ) 

Connect to a positive Voltage output of 8.2 -16Vdc 
source (usually from the alarm control unit) 

Terminals 3 & 4 - Marked “ RELAY ” 

These are the output relays contacts of the 
detector. Connect to a normally closed zone in the 
control unit. 

Terminals 5 & 6 - Marked “ TAMPER ”  

If a Tamper function is required connect these 
Terminals to a 24-hour normally closed protective 
zone in the control unit. If the front cover of the 
detector is opened, an immediate alarm signal will 
be sent to the control unit. 
  

 

FIG. 4 - PCB LAYOUT 

 

10

 

 

11

 

 

12

 

MW SENSITIVITY ADJUSTMENT  
 

JUMPER “JP1”

 

provides sensitivity control of 

MW (DOPPLER) according to the environment

.

 

Position Up – “H” – High sensitivity  

For normal operation – immediately detection. 

Position Down – “L” – Low sensitivity 

For harsh environments.  

 
POTENTIOMETER “RV1” 

– adjustment 

according to protected area range. 
The potentiometer at mid-scale is equivalent to a 
distance of 15m, at min-scale – 7m and         
max-scale - is used with LR lens only. 
 
 

 

Dimension change according to installation 

location and room size 

 

 

 

 

 

 PIR SENSITIVITY ADJUSTMENT 

 
JUMPER “JP4” - 

provides sensitivity control of 

PIR according to the environment.

  

Position Up – “H” – High sensitivity  

For stable environments. 

Position Down – “L” – Low sensitivity

  

For harsh environments.  

 
POTENTIOMETER “RV2” 

– adjustment 

according to protected area range. 
Use RV2 to adjust the detection range between 
68% and 100% (factory set to 84%). Rotate the 
potentiometer clockwise to increase range, 
counter-clockwise to decrease range. 

 

 

 
 

 
 

 

ALARM MODE SETTING  

JUMPER “JP2” OR - AND  

  Position Left “OR”  

 

The alarm signal (relays activation) occurred when 
one of the sensor’s signals - PIR 

OR

 MW - is 

present.  
The effective detection range is the range of the 
PIR pattern 

OR

 MW pattern correspondently. 

Position Right “AND” - 

The alarm signal 

occurred only when both sensors (PIR 

AND

 MW) 

are present at the same time.  
The effective detection range is the range of which 
the PIR patterns 

AND

 MW lobe are intersected. 

 

 

 
You must reset the detector from 
Control Panel before the new 
settings will take effect.

 

2

  

A. 

Wire access 
holes  

B. 

Use for flat 
wall mounting 

C. 

Corner 
mounting - 
use all 6 
holes. Sharp 
left or right 
angle 
mounting - 
use 3 holes 
(top, middle 
and bottom) 

D. 

For bracket 
mounting

 

      -            +           RELAY           TAMPER

 

1       2       3       4        5      6

 

After adjusting the sensitivity perform a 

walk test to verify optimum correct 

sensitivity in the protected area.

  