USER  GUIDE 

Power Wave - 16 

Version 5 

16 Zone Alarm Panel 

Summary of Contents for Power Wave-16

Page 1: ...SERVICING NOTES Please contact your alarm installer if you require further information 25 Oct 2001 USER GUIDE PowerWave 16 Version5 16 Zone Alarm Panel ...

Page 2: ... In basic trim your panel is ready to communicate with monitoring stations and call you at work on your cell phone or pager generating alarm tones Add the Voice Board and your panel will call you with alarm messages in your own voice You can phone your home to check or change the status of any output using the keys on your phone Arm or disarm the whole house or just one area all with your own voic...

Page 3: ...nd you wish to turn on output 5 When the panel picks up your incoming call and after the 5 second tone simply key in 1234 followed by 5 Your voice message will give you the current status of out put 5 To change the status toggle on or off using the key 4 If you make a mistake at any stage press the key and re enter your code 5 When finished simply hang up and the panel will disconnect automaticall...

Page 4: ...or sensors in areas you or your family will not be can be armed with this key while you are in the building and programmed to go into your choice of alarm states if triggered As with everything else on the panel this too can be tailored to your needs For example you may wish to have the detectors in your garage and lounge sound only the little buzzer in the keypad by your bed at night to warn you ...

Page 5: ... the AUX light will glow to indicate zones 9 16 can now be Bypassed It is advisable to vacate the secured area before the exit delay expires The ENTER Key This key is used to accept a series of button presses If you make a mistake while entering your code press the ENTER key and start again Please note that 4 invalid code entries will cause an alarm activation the sirens will sound This is to prot...

Page 6: ...D B The MEMORY Key Your PW 16 alarm panel has an event memory which stores the 225 most recent events including all alarm events all system events such as mains failure etc as well as settings and un settings This event memory is displayed via the keypad with the most recent event shown first and subsequent events following in descending order from newest to oldest Each event is separated by a bee...