The FW-KP is a wireless remote control keypad for POWERWAVE & RUNNER security 

and home automation control panels.  

The FW-KP enables easy programming, arming and disarming of the control panel.  

It also allows to control devices from anywhere in the home or office, using keypad 

commands. 

 FEATURES: 

 

Designed to comply with European Standards 

 

Easy programming  

 

User-friendly operation 

 

Hand-held use and wall mounting 

 

Back light illumination 

 

Visual LED's indications 

 

Audible signals confirm user commands 

 

Up to 300 m range in open space 

 

FSK unique technology 

 

Keypads copy via smart EEPROM  

 

Up to 5 year lithium battery life 

 

Full Supervision 

 

MAKING YOUR FW-KP WORKING WITH A WIRELESS CONTROL PANEL 

1.  INSTALL THE FW-RCV. 

2. ENROLL 

REQUIRED 

OPERATION RADIO SIGNAL (ARM 

/DISARM/STAY/CONTROL. 

3.  SET RADIO PANIC ALARM TO AUDIBLE OR SILENT. 

4.  ACTIVATE OUTPUT BY CHANNEL PANIC IF REQUIRED. 

5.  ACTIVATE OUTPUT BY RADIO CHANEL IF REQUIRED

6.  SET PENDANT CHIRPS FOR ARM/DISARM PARTITION “A” AND PARTITION 

“B” IF REQUIRED. 

 

ENROLLING RADIO CHANNELS 

In order to load a radio command on the panel, press the appropriate address number 

(e.g. P614E for channel 4). 

  

The keypad buzzer will beep once for a second to indicate learn mode has been initiated 

and the FW-RCV board LED will flash. The radio signal you wish to load must transmit a 

signal within 30 seconds from entering learn mode, otherwise the panel will time out and 

no code will be loaded. If a valid code is received within the 30 seconds the keypad will 

Summary of Contents for FW-KP

Page 1: ...1 ELECTRONIC ENGINEERING LTD INSTALLATION INSTRUCTIONS USER MANUAL P N 7101618 Rev B ME YS FW KP WIRELESS KEYPAD...

Page 2: ...G YOUR FW KP WORKING WITH A WIRELESS CONTROL PANEL 1 INSTALL THE FW RCV 2 ENROLL REQUIRED OPERATION RADIO SIGNAL ARM DISARM STAY CONTROL 3 SET RADIO PANIC ALARM TO AUDIBLE OR SILENT 4 ACTIVATE OUTPUT...

Page 3: ...er 1 PROG INSTALLER ENTER PROG ERR PROG User Number ENTER ENTER Installer PROG INSTALLER ENTER PROG ERR PROG 0 ENTER NEW C O D E ENTER HOW TO ENROLL COMMANDS TO THE WIRELESS CONTROL PANEL FIRST Get in...

Page 4: ...back of the FW KP Read from DTU module PROG INSTALLER CODE ENTER COPY 9 ENTER Write to DTU module PROG INSTALLER CODE ENTER COPY 1 ENTER NOTE When the SWITCH is not in WRITE position the data in the D...

Page 5: ...AUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS The battery must be replaced by 3 6V Lithium Battery Size 1 2AA Models as X...

Page 6: ...Low Bat Range in open space up to 300 m Battery Lithium 3 6V Type XL 050F Size 1 2AA Current Consumption Standby 1 A Operator Mode 16 mA Transmission 30 mA Operating temperature Range 0 C to 50 C Dim...

Page 7: ...of the products for a particular purpose or otherwise which extend beyond the description on the face hereof This limited Warranty Certificate is the Purchaser s sole and exclusive remedy against Cro...

Page 8: ...ic 3192 Tel 61 3 9553 2488 Fax 61 3 9553 2688 E mail crow crowaust com au POLAND VIDICON SP ZO O 15 Povazkowska St 01 797 Warsaw Poland Tel 48 22 562 3000 Fax 48 22 562 3030 E mail vidicon vidicon pl...

Reviews: