FW-P100 

 

FREEWAVE™ WIRELESS PIR  

 

    

                                 

 

 
 
 

 

ELECTRONIC ENGINEERING LTD.

 

INSTALLATION INSTRUCTIONS 

P/N  7101405 REV. C  A.Y.

 

 

 

INTRODUCTION 

The FW-P100 is an advanced, fully supervised 

low-current wireless PIR that includes a FreeWave 

transmitter. Both transmitter and detector circuits 

are powered by long life Lithium battery. 

Each FW-P100 has a unique ID code (This code is 

impossible to reproduce). Compatible FreeWave 

receivers are designed to “learn” specific IDs and 

respond only to them. 
Following detection, FW-P100 triggers the on-

board transmitter that transmits its specific 

FreeWave ID followed by an alarm signal and 

status designators for battery condition. If detector 

cover is removed Tamper Event triggers the on-

board transmitter. 

 Alarm and other data are forwarded to the alarm 

control panel. A periodic test transmission for 

supervision purpose takes place automatically 

once in 12~14 min. The receiver is informed that 

the particular detector is taking an active part in the 

wireless security system. 

 

 

 

The FW-P100 has unique Alarm Power Saver 

(APS) mechanism that enables transmitter 

activation only 2 min after the last movement has 

been detected. 

FEATURES 

  State-of-the-art wireless security system 
  Low current ASIC PIR Technology 
  Powered by a 3Volt Lithium battery 
  Battery life : up to 4  years 
  Built in Automatic Power Saver (APS) 
  Frequency Band: 868MHz,433MHz 
  Low Battery condition signal transmission 

  Test mode for PIR coverage and RF signal. 
  Range up to 1 km at free space. 
  Height installation calibration free (1.5m - 3.6m).  
  Unique ID number 

 

4

 

 

5

 

 

6

 

OPERATION 

The Wireless PIR transmits the following events 

data: 

SUPERVISION

 - 

a periodical transmission.

 

Every 12~14 min indicates detector’s presence. 

ALARM

 – alarm transmission triggered by PIR 

intrusion detection.  

LOW BAT

 – Whenever the battery reaches a pre-

set low level (2.4V) Battery Low signal will be sent 

with the next message (Supervision, Alarm, etc). 

TAMPER

 – Whenever the FW-P100 cover is 

removed or the unit’s cover is put back, a 

message will be transmitted with “Tamper” 

signal. 

APS  

The unique APS (Automatic Power Saver) function 

built in the detector enables a battery life span up 

to four years. The detector will transmit only when 

the last event has occurred more than 2 minutes 

prior to the current one.

  

 

 

SELECT MOUNTING LOCATION 

Select the mounting location so that an intruder 

will cross the beams of the selected pattern. 

As the detector is a wireless transmitter, and in 

order to take full advantage from PIR 

sophisticated operation, do not install the 

detector in areas where large metal objects 

could interfere the transmission of signals. It is 

also advisable to avoid following locations: 

  Facing direct sunlight. 
  Facing areas that may change temperature 

rapidly. 

  Areas where there are air ducts or 

substantial airflows. 

  Installation on metal wall. 

The FW-P100 performs better when provided 

with a constant and stable environment.  

 

FIG. 1 - REMOVAL OF FRONT COVER 

 

 

 

 

 

7

 

 

8

 

 

9

 

MOUNTING THE DETECTOR 

1. To remove the front cover, unscrew the holding 

screw and insert a flat screwdriver in the slot 

between the front and the bottom above the 

holding screw hole and push gently, until the front 

cover is disengaged and the opening click is 

heard.(Fig. 1) 

2.  To remove the PC board, carefully unscrew the 

holding screw located on the PC board. 

3.  Break out the desired holes for proper installing.  

4. Mount the detector base to the wall, corner or 

ceiling.  

5. Reinstall the PC board by fully tightening the 

holding screw.  

6. Before battery replacement capacitors discharge 

must be done - use flat screwdriver to make 

momentary short circuit for JP2 pins.(Fig. 3) 

7.  Install battery in the battery holder according 

polarity. 

8. Replace the cover by inserting it back in the 

appropriate closing pin until the closing click is 

heard. 

 

FIG. 2 - KNOCKOUT HOLES 

 

 

FIG. 3 - CIRCUIT LAYOUT 

 

 

10 

 

11

 

 

12

 

SETTING UP THE DETECTOR (Fig. 3)

  

The sensitivity adjustment jumper sets up the 

detector for normal or harsh environment 

condition.  

 

Setting the Sensitivity Adjustment (Pulse 

Width) Jumper 

 

  Position 1= Normal  
  Position AUTO = Harsh 

The “1” position setting is for normal operation.    
The “AUTO” position setting is for harsh 

environment locations with air drafts or small 

animals. 
 
 
 

 

 

RSSI – RF SIGNAL INDICATION 

The FREEWAVE control panel has “RF Signal 

quality Indication” for each transmitter in order 

to help the installer to define best location for 

the detector from RF point of view. 

The indication value is between 1 and 100, 

where 100 is the best RF received signal. If 

the RSSI indication is less then 30, it is a sign 

for weak RF link, try to find a better installation 

for the PIR.  

 

NOTE:  

See FREEWAVE control panel installation 

instruction. 

 

 

ID REGISTRATION - “LEARN” 

PROCEDURE 

Refer to the system receiver’s installation 

instructions and follow the procedure given there 

for “learning” detector IDs.  

Perform transmission by pressing and 

releasing tamper switch for learning it by 

FREEWAVE control panel receiver.  

Make sure that the receiver is at learning 

mode - according to control panel installation 

instruction. 

 

 

NOTE: 

It is recommended to power up the detector and let 

the system receiver “learn” the detector’s ID before 

actual installation. 

 

A.   Not in use  

B.   Use for flat 

wall mounting 

C.   Corner 

mounting - 

use all 4 

holes. Sharp 

left or right 

angle 

mounting - 

use 2 holes 

(top and 

bottom) 

D.   For bracket 

mounting 

 