background image

 

The  CSB-60  is  a  bi-station  microwave  detector  for  outdoor  applications.  It 

comprises  a  transmitter  (T)  and  receiver  (R)  which,  when  mounted  facing  each 

other, create a perimeter protection with coverage of up to 60m. The dimensions of 

the antenna’s lobe vary according to the chosen antenna, the distance between the 

two units and the selected system sensitivity. 

The  CSB-60  Microwave  barrier  is  an  advanced  detector  utilizing  state  of  the  art 

Microwave  technology  eliminating  false  alarms  while  maintaining  high  security 

standards for the detection of human intruders into a protected area. 

The CSB-60 is designed to protect large areas and can easily be installed on any 

type  of  fence  or  pole  in  order  to  provide  a  solid  barrier  protection  and  block  all 

perimeter activities; this barrier rejects interferences of birds and small animals due 

to its original method of false alarm elimination. 

Several CSB-60 systems can be combined in order to provide a complete perimeter 

protection with unlimited space or shape. 

The  CSB-60  is  designed  for  continuous  round-the-clock  operation  and  keeps  its 

characteristics within a wide temperature range of -40°C up to +60°C and a relative 

humidity of up to 98%. 

 

Features: 

  Detection Range:    

Up to 60m 

  Operating Temperature:   -40

°

C to +60

°

  Power Input:   

 

12 ~ 30 Vdc 

  Detect human intruders walking, running or crawling. 

  Quick and easy installation on pole, fence or wall. 

  No maintenance required. 

  High RFI/EMI Immunity. 

  Protection from: Power supply failure, direct sunlight, wind up to 30 m/sec, snow 

and  rain,  small  animals,  ground  precipitation,  snow  and  grass  up  to  0.5m, 

removing  the  top  cover,  housing  destruction,  electromagnetic  masking  of  the 

receiver. 

 

Summary of Contents for CSB - 60

Page 1: ...1 ELECTRONIC ENGINEERING LTD INSTALLATION INSTRUCTIONS USER MANUAL P N 7111060 Rev 1 0 Y S A Y CSB 60 Microwave barrier Outdoor Detector 60m Range...

Page 2: ...tion and block all perimeter activities this barrier rejects interferences of birds and small animals due to its original method of false alarm elimination Several CSB 60 systems can be combined in or...

Page 3: ...g locations Avoid installation of CSB 60 on the following type of ground Thick vegetation Grass unmown Water Sand and a Metal The ground must not have movable parts near the sensitive zone any grassy...

Page 4: ...ds connected to the bracket and ensure reliable fastening of the bands The unused part of bands may be cut off Connect the plastic housing to the bracket using the nuts with the spherical support Top...

Page 5: ...ap Receiver Receiver Receiver Transmitter Transmitter Transmitter Transmitter T r a n s m it t e r Transmitter T r a n s m it t e r Receiver R e c e i v e r Receiver R e c e i v e r Fig 2 Overlap inst...

Page 6: ...ont cover of the detector is opened an immediate alarm signal will be sent to the control unit Terminals 5 6 7 Marked NO C NC These are the output relay contacts of the detector Connect to normally cl...

Page 7: ...6 Control Unit and CSB 60 Wiring Diagram 1 2 3 12V TAMP NO C NC Sensitivity Jumper Tamper switch Receiver board Transmitter Board TEST POWER SUPPLY 12 30 V ALARM BOARD For normal closed alarm circuit...

Page 8: ...position 2 as shown in fig 5 To increase the sensitivity set jumper to position 1 To decrease the sensitivity set jumper to position 3 3 Adjustment of the aerials receiver and transmitter For the opti...

Page 9: ...received in the control unit for 3 Sec NOTE Walk Test procedure should be conducted at least once a year to confirm proper operation and coverage of the detector Remote Test Apply 5 30 Volts from cont...

Page 10: ...urrent 0 1 A open when cover is removed Detection Speed Target velocity 0 3 10 m sec Remote testing Built in self test generator simulates actual intrusion signals Flatness of ground Approx 0 3 m Maxi...

Page 11: ...other basis of liability whatsoever even if the loss or damage is caused by CROW s own negligence or fault CROW does not represent that this product can not be compromised or circumvented that this pr...

Page 12: ...TRALIA CROW AUSTRALIA PTY LTD 429 Nepean HWY Brighton East Vic 3187 Tel 61 3 9596 7222 Fax 61 3 9596 0888 E mail crow crowaust com au POLAND VIDICON UL PLOCKA 17 01 231 WARSZAWA POLAND Tel 48 22 632 5...

Reviews: