CROW ELECTRONIC ENGINEERING NEO DT Installation Instructions Download Page 2

 

 

 SETTING UP THE DETECTOR 

 

 

 

 

 Switch 4 – Marked M - MW SENSITIVITY Setting 

 

Used for setting the MW functions in order to provide 
MW sensitivity control according to the environment. 

** 

ON Position (Up) 

- Low sensitivity, for harsh 

environments. 

 Testing the Detector - WALK TEST 

                

Upon installation, the unit should be thoroughly tested 
to verify proper operation. 

Apply 12 Vdc power to the detector, wait 2 minutes to 

 
 

J4 
2/4 MODE 

EOL TAMPER 2/4 

J5 

J4 

1 2 3 4 

EOL ALARM 

 
 

1  2  3  4 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

P/N3203974 

 
 

 

PIR 

 
 
 

 

  

 

 

J3 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

L P W M A 

OFF Position (Down) 

- High sensitivity, for normal 

operation - immediate detection. 

 Switch 5 – Marked A – AND/OR Mode 

 

Used for setting the ALARM indication mode 

** 

ON Position (Up) 

– AND mode, Alarm will activate 

upon PIR 

AND 

MW detection. 

OFF Position (Down) 

– OR mode, Alarm will activate 

upon PIR 

OR 

MW detection. 

 

** Note: Marked (**) positions are the factory default 
setting of the detector. 

 RANGE ADJUSTMENT 

 

“MW” POTENTIOMETER 

- adjustments according to 

protected area range - see fig.5&6. 
The potentiometer at mid-scale is equivalent to a 
distance of 15m, at min-scale - 7m. 
Rotate the potentiometer clockwise to increase range, 
counter-clockwise to decrease range. 

Dimension change according to installation 
location and room size. 

PIR” POTENTIOMETER 

- adjustment according to 

finish the detector warm up time. Conduct testing with 
the protected area cleared of all people. 

Walk test 

1.  Remove front cover. 
2.  Make sure that 

PIR and MW 

switches are in 

positions high sensitivity. 

3.  Make sure that 

LED 

switch is 

ON

4.  Replace the front cover. 
5.  Start walking slowly across the detection zone. 
6.  Observe that the detector

s LED lights whenever 

motion is detected. 

7.  Allow 5 sec. between each test. 
8.  After the walk test is completed, the 

LED, PIR and 

MW 

switches may be changed. 

 

NOTE: Walk tests should be conducted, at least 
once a year, to confirm proper operation and 
coverage of the detector 

 

 Visible Light Filter Option 

                                         

Use the optional white light filter in order to improve the 
detector stability to high intensity visible light. 

T

he dip switch selector mounted on the unit’s pc 

board controls the functions setting of the detector: 

 Switch 1 – Marked L - LED Enable 

 

Used for setting LED Enable / Disable 

** 

ON Position (Up) 

– all LED's enabled. 

OFF Position (Down) 

– all LED's disabled. 

Note: the state of the switch “LED” does not affect the 
operation of the ALARM and TROUBLE relays 

 Switch 2 – Marked P - PIR SENSITIVITY Setting 

   

Used for setting the PULSE count function in order to 
provide PIR sensitivity control according to the 
environment. 

** 

ON Position (Up) 

- High sensitivity for stable 

environments, One motion event trips the PIR. 

OFF Position (Down) 

- Low sensitivity for harsh 

environments, Two motion events trip the PIR. 

 Switch 3 – Marked W - PET IMMUNITY Setting 

     

Used for setting the PET Immune function 12Kg or 
25Kg, depending on the pet Weight. 

** 

ON Position (Up) 

- Immunity to an animal up to 

12kg 

OFF Position (Down) 

- Immunity to an animal up to 

25kg 

 

 

 EOL Connection Options 

                                     

The End-Of-Line connection options are described in 
the following drawings. 
Set 

J4 JUMPER “2/4” 

according to connection option 

Set 

J5 “REOL” and J3 “RAL” Jumpers 

according to 

EOL resistors value (see fig. 3) 

 Option A - 4 Wire Connection with EOL 

 

protected area range - see fig.5&6. 
Use the Potentiometer marked “PIR” to adjust the 
detection sensitivity between 30% and 100%, according 
to walk test in the protected area. 
Rotate the potentiometer clockwise to increase range, 
counter-clockwise to decrease range. 
After adjusting the sensitivity perform a walk test to 
verify optimum correct sensitivity in the protected area. 

 LED VISUAL INDICATIONS 

 

There are three LED's on the unit’s PC board to signal 
various detector events 

  

  

 

 Option B - Connecting single detector with 2 wire and EOL resistors 

 

 
 
 
 
 

 

 Option C - Connecting multiple detectors with 2 wire and EOL resistors 

 

 
 
 
 
 

 

TECHNICAL SPECIFICATION 

Detection Method 

PIR & Microwave pulse Doppler 

Detection Range 

2 ~ 15m @ H=1.8 ~ 2.4m 

MW Freq. - X Band 

10.525GHz / 10.687GHz / 9.9 GHz 

Power Input 

9.6 to 16

Vdc 

Current Draw 

Active:     

35mA 

(+/- 5%) 

Standby:  

22mA 

(+/- 5%) 

Temp Consumption 

Yes 

Alarm Period 

± 

1 sec 

Form C - NC&NO 

 STANDARDS COMPLIANCE 

 

European Council Directive 2004/108/EC 
EN50130-4+A1+A2 
EN301489-3 
EN301489-1 
EN61000-6-3 
EN50130-5 
EN50131-1 
EN50131-2-4 
EN50131-6 
SAFETY LVD 2006/95/EC 

 CROW ELECTRONIC ENGINEERING LTD. 

 

CROW ELECTRONIC ENGINEERING LTD. 

12 Kineret St. 
Airport City, 70100 Israel 
Tel. +972 3 9726000 
Fax. +972 3 9726001 
[email protected] 
[email protected] 

www.thecrowgroup.com 

CROW LATIN AMERICA USA INC. 

7200 NW 19 st. 

Alarm Outputs 

28Vdc 0.1 A with 10 Ohm 
series protection resistors 

EN60950-1 (93/68/EEC) 
Security Grade 2, Environmental Class II 

Suite 307 
Miami FI 33126, USA 
Tel. +305 513 4001 

AM / Trouble Output 

Form A N.C 28Vdc 0.1 A with 
10 Ohm series protection resistors 
open when cover is removed 

N.C 28Vdc 0.1 A with 10 Ohm 

For more detailed instruction please refer the manuals 
which you could download from the internet at: 

www.thecrowgroup.com 

Fax. +305 513 4005 
[email protected] 

www.crowlatinamerica.com 

ARROWHEAD ALARM PRODUCTS 

Tamper Switch 

series protection resistors 
open when cover is removed 

344B, Rosedale Road 
Park Farm Industrial Estate 
Albany, Auckland 

Warm up Period 

1min 

Operation Temp 

-10

º

C ~ +50 

º

C (14 

º

F~122 

º

F) 

Dimensions 

116 mm x 60mm x 37mm 

Weight 

105gr. 

 

N345 

 
 
 

P/N 7101740 Rev C YS 

New Zealand 
Tel. +64 9 414 0085 
Fax. +64 9 414 0088 

www.aap.co.nz 

These instructions supersede all previous 
issues in circulation prior to March 2012. 

 

For warranty policy and conditions please refer to CROW ELECTRONIC ENGINEERING Ltd. - WARRANTY POLICY CERTIFICATE on www.thecrowgroup.com 

(3) 

Insert the FILTER into 

the two slots at lens 

housing corners 

(4) 

To fit lens press it into 

the cover from the front 
until "CLICK" is heard 

Event 
Message 

RED 

GREEN 

YELLOW 

Initial warm- 
up (60Sec.) 

 

 

 

No Detection 
Standby 

 

 

PIR walk-test 
detection 

 

 

2Sec 

MW walk-test 
detection 

 

 

2Sec 

ALARM 

 

2Se c 

 

 

Note: The detector should be reset after any change 
by removing and applying the 12V power supply. 

BLOCK 
TERMINAL 

TIN TOUT TEOL AIN AOUT SPR TEST + 12V - 

ALARM 

TAMPER 

MW MODULE 

J5 
EOL TAMPER 

J3 
EOL ALARM 

RED LED 
ALARM 

GREEN LED 
PIR 

PIR SETTING 

DIPSWITCH 

TAMPER 

MW SENS. 
SETTING 

YELLOW LED 
MW 

(2) 

Bend the FILTER 

and place in the center 

of lens housing 

(1) 

Remove lens, by pressing 

both lens hooks to outside and 
pushing the lens to the front. 