Crosswater WP120WNC Installation Instructions Download Page 3

3

4

INSTALLATION

INSTALLATION

First shut off your water heating system then, with your mains stop cock closed, 
open the lowest hot and cold taps in the house and allow to run until the cold storage 
tank and pipes are empty (the hot water storage cylinder always remains full).
Where combination boilers are fitted it is only necessary to turn off the boiler and 
shut off the incoming mains.
Fitting isolating valves to the inlet feeds is recommended for ease of maintenance.

INSTALLATION
           Remember to turn off the mains water supply before connecting to any 
           existing pipe work.
           Warning! Please check for any hidden pipes and cables before drilling 
           holes in the wall
        

!

Mounting plate

A recess must be made in the wall to accommodate the mounting plate, mixer and 
flexible hoses. 
Place the mixer in position, check to see if any alterations are needed to the existing 
pipe work.
Secure the mounting plate into the recess in the wall.

Connect the water supply to the tap with hot water on the left and cold on the right.
(When viewed from the front).

Once you have satisfied yourself that there are no leaks, switch on the water heating.

!

Valve

Apply a narrow bead of clear silicone sealant around the back edge of the cover 
plate and carefully press into position. 

ATTENTION

Having first checked all new connections, turn on the mains stop cock, close all taps 
except the new mixer and as the system starts to refill check for leaks.

WASHER

WASHER

FIXING SCREWS

MAIN OUTLET

(SPOUT)

MOUNTING PLATE

VALVE

COLD INLET

HOT INLET

WP120WNC

FIG. 2  INSTALLATION OF HANDLES

FIG. 1 INSTALLATION OF SPOUT 

COVER PLATE

SPOUT

HEXAGONAL 
KEY

SCREW
COVER

HANDLE

COVER PLATE

HEXAGONAL 
KEY

SCREW
COVER

Reviews: