To set the temperature, remove the handle and unscrew the centre 

screw of the thermostatic control cover.

 

Rotate the exposed thermostatic spindle, (clockwise for cold and 

anti-clockwise for hot), until the maximum desired temperature is 

set (107°F - suggested maximum ‘pre-set’ temperature).

 

Position the tab on the back of the control cover to the same side as 

the stop on the cartridge.

 

Push the control cover onto the splines and tighten the centre 

screw.

 

 

The thermostat is now set to its new temperature and can only be 

increased or decreased by repeating this process.

NOTE: To avoid damage, please remove all chrome parts before 

maintenance takes place.
Thermostatic cartridges

 

The 1” concealed thermostatic valve should give trouble free 

service, but in the event of failure servicing is a straight forward 

process.

To remove the thermostatic cartridge

 

Undo the cartridge clamp nut, (take note of the orientation of the 

cartridge).

 

Pull the cartridge out using the temperature control knob to aid 

removal.

 

Wash the cartridge with clean running water and make sure that 

any trapped debris has been removed.

 

Dry and lightly grease the seals, (only use silicone grease), and 

replace the cartridge making sure that the recess on the body of 

the valve is aligned with the slot in the raised central section of the 

plastic cartridge. This is to make sure the stop is in the required  

2 o’clock position shown.

Flow control cartridge

 

cartridge and replace with a new one.

Filters/check valves

 

supplies.

To clean the check valve

 

Undo and remove the check valve. 

 

 

seals, (only use silicone grease).

Care of your shower valve

 

We recommend cleaning the valve with a soft damp cloth.

 

We strongly advise against the use of ALL cleaning products.

Temperature control

Maintenance

THERMOSTATIC

CARTRIDGE

THERMOSTATIC

SPINDLE

STOP

SEALS (x3)

RECESS

SLOT ON

CARTRIDGE

STOP

CARTRIDGE

CLAMP NUT

FILTER

NON RETURN

VALVE

CHECK

VALVE

Summary of Contents for US-DL2001RC

Page 1: ...d retain for future reference Roughing in dimensions Tools required NOTES The installation must comply with all plumbing codes including local codes This valve is a mixing device and therefore requires the water supplies to be reasonably balanced otherwise we unbalanced line pressures Fitting isolating valves to the inlet feeds is recommended for ease of maintenance before connecting to any existi...

Page 2: ... Installation Installation Flow cartridge Screw ring on the thermostatic body 2 A Attach chrome ring 4 on the control cover 3 Place the handle 5 with the screw positioned downward and tighten screw Thermostatic control Attach control cover 7 to the thermostatic cartridge position tab of the cover to the same side as the tab on the cartridge 8 9 do not turn the spindle tighten screw NOTE Pay attent...

Page 3: ...dge Undo the cartridge clamp nut take note of the orientation of the cartridge Pull the cartridge out using the temperature control knob to aid removal Wash the cartridge with clean running water and make sure that any trapped debris has been removed Dry and lightly grease the seals only use silicone grease and replace the cartridge making sure that the recess on the body of the valve is aligned w...

Page 4: ... 8 3 4 5 6 7 25 14 5 30 44 Symptom After installation the shower runs HOT or COLD and will not mix Shower will not run hot Cold water tracking through the valve into the hot water system Solution Hot and cold supplies are plumbed the wrong way round The hot and cold supplies need to be redone to the correct inlets as marked and described in the installation Maximum temperature needs adjusting see ...

Reviews: