WASHER
HANDLE
RETAINING
NUT
BRASS
SLEEVE
SCREW
GASKET
SLEEVE
DIVERTOR
CARTRIDGE
PIN
HEXAGONAL
KEY
WASHER
HANDLE
RETAINING
NUT
BRASS
SLEEVE
SCREW
COUPLING
GASKET
STOP
PIN
HEXAGONAL
KEY
THERMOSTATIC
CARTRIDGE
Cleaning the divert
e
r cartridge
l
The divert
e
r cartridge should give trouble
-
free service,
however
servicing is a straightforward process.
To remove the divert
e
r cartridge
:
l
With
the
water supply
turned off
, unscrew the pin on the handle
taking care not to mark the
finish
.
l
Using a hexagonal key loosen the
set
screw but do not remove.
l
Remove the handle and gasket.
l
Undo the retaining nut and pull the divert
e
r cartridge out with the
sleeve and brass sleeve attached.
l
Wash the divert
e
r cartridge with clean running water, dry and
lightly grease the seal, (only use silicone grease).
l
Replace the divert
e
r cartridge followed by the retaining nut, gasket
and handle.
Thermo
static
cartridge
l
The thermo cartridge should give trouble
-
free service,
however
se
rvicing is a straightforward process.
To remove the thermo
static
cartridge
:
l
With
the
water supply
turned off
, unscrew the pin on the handle
taking care not to mark the
finish
.
l
Using a hexagonal key loosen the
set
screw but do not remove.
l
Remove the handle and gasket.
l
Remove the coupling, (take note of the orientation of the coupling).
l
Undo the retaining nut and pull the thermo cartridge out with the
brass sleeve attached.
l
Wash the thermo
static
cartridge with clean running water and
make sure that any trapped debris has been removed.
l
Dry and lightly grease the seals, (only use silicone grease), and
replace the thermo cartridge.
l
To re-assemble, reverse the sequence above taking care to replace
the coupling in the same orientation before removal.
4
Maintenance
Thermo cartridge -
S
et temperature to
desired maximum
To set the thermo cartridge
:
l
With
the
water supply
turned off
, unscrew the pin on the handle
taking care not to mark the
finish
.
l
Using a hexagonal key loosen the
set
screw but do not remove.
l
Remove the handle and gasket.
l
Remove the stop ring, (take note of the orientation of the stop ring).
l
Adjust the temperature of the thermo cartridge to
desired maximum.
l
To re-assemble, reverse the sequence above taking care to replace
the stop ring in the same orientation before removal.
Vertical marking
HANDLE
STOP
RING
STOP
RING
HEXAGONAL
KEY
THERMOSTATIC
CARTRIDGE
PIN