Crosswater KL322DC Installation Instructions Download Page 3

3

4

INSTALLATION

INSTALLATION

First shut off your water heating system then, with your mains stop cock closed, open the 
lowest hot and cold taps in the house and allow to run until the cold storage tank and pipes 
are empty (the hot water storage cylinder always remains full). Where combination boilers 
are fitted it is only necessary to turn off the boiler and shut off the incoming mains.
Fitting isolating valves to the inlet feeds is recommended for ease of maintenance.

        

!

Remove the fixing nuts, plastic and rubber washers from the tap tails.
Insert the tails into the holes on the bath top making sure that the O ring and mixer base ring 
are correctly positioned.
From beneath slide on the rubber washer, plastic washer followed by the nut.
Secure the tap finger tight with the nuts, check that the tap is correctly positioned to the rear 
and tighten fixing nut. The tap needs to be fixed firmly but do not over tighten as damage 
may be caused to the bathtub.

Connect the water supply to the tap with hot water on the left and cold on the right.
(When viewed form the front).

Once you have satisfied yourself that there are no leaks, switch on the water heating.

KL322DC

  

INSTALLATION
           Remember to turn off the mains water supply before connecting to any existing 
           pipe work.

ATTENTION

Having first checked all new connections, turn on the mains stop cock, close all taps except 
the new mixer and as the system starts to refill check for leaks.

MAINTENANCE

CAP

MIXER HANDLE

HEXAGONAL

KEY

SEAL
CARTRIDGE

MIXER BODY

CLEANING THE CARTRIDGE

The concealed cartridge should give trouble 
free service, but in the event of any problems, 
servicing is straight forward.

To remove the cartridge.

Pull off the cover cap and with an hexagonal key 
loosen the screw, but do not remove it. Pull off the 
handle. Using the correct size spanner unscrew 
and remove the cartridge. Wash the cartridge with 
clean running water and make sure that any 
trapped debris has been removed. Dry and lightly 
grease the seal (only use silicone grease) and 
replace the cartridge followed by the handle.

CLEANING

The chrome and gold plate we use on our taps is very durable, nevertheless care

 should be 

taken when cleaning

 them. They should be cleaned only with warm soapy water followed

 by 

rinsing with clean water and drying with a soft cloth. All finishes are vulnerable

 to acid attack 

and some strong substances such as

 household cleaners, disinfectants,

 denture cleaners, 

hair dyes, wine making and photographic

 chemicals can cause

 the surface to go black or peel.

HOT
CONTROL
HANDLE

MIXER BODY

RUBBER
WASHER

RUBBER
WASHER

PLASTIC
WASHER

NUT

RUBBER
WASHER

PLASTIC
WASHER

NUT

FLOW STRAIGHTENER

COLD
CONTROL
HANDLE

BATHTUB

MIXER BASE
RING