15123035
6
15-16-T-PC
15-16-T-SN
15-16-T-PN
Applicable Standards/Codes
Installation Dimensions
15123035
3
10
11
Rotate the cartridge stem to adjust
safety temperature. Rotate clockwise
to reduce temperature, rotate
counterclockwise to increase the
temperature. Once the temperature
is 100ºF go to step #12.
Turn off the water supply. Remove
temperature control handle and
escutcheon.
IAPMO certified to meet or exceed the following:
$60($&6$%
8QLIRUP3OXPELQJ&RGH
1DWLRQDO3OXPELQJ&RGHRI&DQDGD
$'$&RPSOLDQW
ʾ
ʾ
7
ʾ
3
ʾ
ʾ
ʾ
ʾ
ʾ
5
ʾ
-
ʾ
137
13
The valve maximum temperature is
set at 107ºF. Should your customer
OLNHWRFKDQJHWKLVJRWRVWHS
If not go to step #19.
14
Turn off the water supply. Remove
handle, escutcheon.
Rotate the inner white temperature
range control ring to adjust
temperature. Rotate clockwise to
reduce the maximum temperature,
rotate counterclockwise to increase
the maximum temperature.
Reinstall the inner white temperature
range control ring.
12
Reinstall the temperature control
handle and escutcheon making sure
the temperature override button is on
top and the handle is set at 6 o'clock.
15
Remove the inner white temperature
range control ring.
18
Reinstall handle, escutcheon.
100
o
F
Safety
Temperature
107
o
F
Hottest
Temperature
16
17