Crosswater Arcade US-H401-ARC Installation Instructions Manual Download Page 6

HAND

LE

HAND

LE

COVER CAPS

SCREW

THERMOSTATIC 

CARTRIDGE

Replacement part

US-WLBGEXPVLVCAR

LOCKING

NUT

STOP

RING

BRASS

RING

VALVE

COVER

HAND

LE

HAND

LE

COVER CAPS

SCREW

SET

 SCREW

The 1” concealed thermostatic valve should give trouble

-

free 

service

 however 

servicing is a straightforward process.

To remove the thermostatic cartridge

Gently unscrew the cover cap from the handwheel.

Undo the long screw and dissasemble the parts as shown.

Undo the cartridge locking nut, (take note of the orientation of the 

cartridge).

Pull the cartridge out of the mixer housing.

Wash the cartridge with clean running water and make sure that 

any trapped debris has been removed.

Dry and lightly grease the seals, (only use silicone grease), and 

replace the cartridge.

Re-assemble all parts.

9

 

Cleaning Instructions

Rinse away any traces of soap and gently dry with a clean, soft cloth after each use. Rinse completely with water and dry any overspray. This will 
maintain the finish and avoid water spotting. 
To remove mineral deposits, use a 50/50 solution of white vinegar and water. Do not allow the solution to soak on the product. Simichrome 
Polish® contains a protective film to enhance maintenance and is helpful in preventing water spot buildup. Follow instructions to ensure 
optimum results. 
Never use an abrasive material such as a brush or scouring pad to clean the surface. The use of abrasive cleaners, cleansers or disinfectants will 
alter the surface finish and void the warranty. 
Do not allow certain materials such as toothpaste, cologne, shaving cream, nail polish remover, vinegar, wine, drain and glass cleaners to 
remain on the surface. Prolonged contact will alter surface finishes and void the warranty.

We DO NOT recommend using any household cleaners as many can cause damage to the finish. 

Please see the website for care instructions for specific finishes. 

Maintenance for thermostatic valve US-ARC1000EV

 

NOTE: 

To  avoid  damage,  please  remove  all 

plated

  parts  before 

maintenance takes place. 

 

Thermostatic

 

cartridges

Summary of Contents for Arcade US-H401-ARC

Page 1: ...8 22 3 8 3 4 6 3 4 9 1 4 Adjustable wrench Channel locks Plumbers putty or caulking Flat head screwdriver Cross head screwdriver Hexagonal key ON OFF ON OFF This exposed valve is suitable for use with...

Page 2: ...uctions Arcade Exposed Thermostat Riser Kit Arcade Soap Dish For Riser Arcade Handshower Cradle For Riser Arcade Wall mount Straight Shower Arm Arcade 9 Shower Head Arcade Handshower Hose Make sure th...

Page 3: ...e riser rail to the top outlet To install the bottom spout remove the stop located at the bottom of Turn on the water supplies and test all connections for water leaks Installation Installation 4 SET...

Page 4: ...if necessary Installation 5 Required Height ALLEN KEY SET SCREW RISER SCREW WALL PLUG BACK PLATE RISER 2mm 2 5mm SET SCREW ALLEN KEY SHOWER ARM RISER WASHER Installation 6 Assemble the shower arm onto...

Page 5: ...Installation 7 Assemble the shower head Installation 8 Connect the hose to the valve body and put the handshower on the cradle 6a HANDSHOWER HOSE FILTER WASHER 6b SHOWER HEAD WASHER FILTER SHOWER ARM...

Page 6: ...nd dry any overspray This will maintain the finish and avoid water spotting To remove mineral deposits use a 50 50 solution of white vinegar and water Do not allow the solution to soak on the product...

Page 7: ...ord MA 01757 Toll free number 844 XWATER 1 844 992 8371 tel 508 381 0433 fax 508 381 6068 www crosswaterlondon com email technical crosswaterlondon com Issue date 15092019 THERMOSTATIC CARTRIDGE Repla...

Reviews: