AHRS500CA Series User’s Manual
Doc# 7430-0050-03 Rev. A
Page 3
2 Quick Start
2.1
GyroView Software
Crossbow includes GyroView software to allow you to use the
AHRS500CA right out of the box and the evaluation is straightforward.
Install the GyroView software, connect the AHRS500CA to your serial
port, apply power to your unit and start taking measurements.
2.1.1
GyroView Computer Requirements
The following are minimum capabilities that your computer should have to
run GyroView successfully:
•
CPU: Pentium-class
•
RAM Memory: 32MB minimum, 64MB recommended
•
Hard Drive Free Memory: 15MB
•
Operating System: Windows 95, 98, NT4, 2000
2.1.2
Install GyroView
To install GyroView in your computer:
1. Insert the CD “Support Tools” in the CD -ROM drive.
2. Find the GyroView folder. Double click on the setup file.
3. Follow the setup wizard instructions. You will install GyroView
and a LabView Runtime Engine. You will need both these
applications.
If you have any problems or questions, you may contact Crossbow directly.
2.2
Connections
The AHRS500CA is shipped with a calibration/maintenance cable to
connect the AHRS500CA to a PC communications port.
1. Connect the 15-pin female end of the digital signal
calibration/maintenance cable to the port on the AHRS500CA.
2. Connect the 15-pin male end of the digital signal
calibration/maintainance cable to the cable harness connector that
supplies power to the DMU.
3. Connect the 9-pin end of the calibration/maintenance cable to the
serial port of your computer.
4. Bolt the base of the unit to a grounded surface. A good ground is
required for EMI and lightning over-voltage protection.