background image

1.2   Technical Characteristics

(Technical characteristics continued on page 5...)

4116-21T23 Manual, Rev. B  

 

      Page 4

    

                     09/24/15  

 +10 dBm, maximum gain

   Output 1 dB Compression 

 ± 0.05 ppm maximum over temp internal reference; external reference input

   Frequency Accuracy

 -60 to 0 dBm

   Output Gain Adjustment

 SIGNAL RELATED <-50 typical, -45 minimum dBc; SIGNAL INDEPENDENT,

  <-60 dBm, 2.20-2.30 GHz, maximum gain

   Spurious, Inband

 

TABLE 1.0

 4116-21T23 Translator Specifications**

 Input = +2 to +8 dBm in. Monitor Output = Input Level ± 1.0 dB, 50

Ω

   10 MHz Level In/Mon

 None; Fixed Translation 

   LO Step Size 

 LO Characteristics

 Non-inverting

   Frequency Sense

 ±1.5 dB, over RF band; ± 0.5 dB, 40 MHz BW  

   Frequency Response

 <-50 dBc for two carriers at 4 MHz spacing, each at -5 dBm out, maximum gain

   Intermodulation

 <-50 dBm spurious, signal independent; 1.0-2.19 and 2.31-3.0 GHz out, max. gain

   Spurious, Out of Band

 > 45 dB, minimum, at +0 dB gain

   Input to Output Isolation

 4±2 dB maximum, (+0 to -60 dB variable in 1±1 dB steps)

   Gain at Fc

 Channel Characteristics

 >50 dB @ 0 dBm Output

   Mute 

 2.20 to 2.30 GHz

   Frequency

 50

Ω

 / 14 dB, Mute & UnMute

   Impedance/Return Loss

 

Output Characteristics

 -30 to 0 dBm

   Input Level Range

 24 dB at maximum gain

   Noise Figure, Maximum

 2.02 to 2.12 GHz

   Frequency

 50

Ω

/14 dB

   Input Impedance/Return Loss

 

Input Characteristics

 Green LED

   Power

 Gain and internal 10MHz frequency via Ethernet M&C or Status/Control Connector

   Gain, 10M Frequency

 Red LED, External Contact Closure

   PLL Alarm

 

Controls, Indicators

-110

-95

-80

-70

-70

1 MHz

100 kHz

10 kHz

1 kHz

100 

                              dBC/Hz

   Phase Noise @ F (Hz) >

Summary of Contents for 4116-21T23

Page 1: ...cated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equip...

Page 2: ...gainst defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies...

Page 3: ...igned to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be located out in...

Page 4: ...sponse 50 dBc for two carriers at 4 MHz spacing each at 5 dBm out maximum gain Intermodulation 50 dBm spurious signal independent 1 0 2 19 and 2 31 3 0 GHz out max gain Spurious Out of Band 45 dB mini...

Page 5: ...or MS3116F14 18P Contact Closure Alarms RS232 422 485 Ethernet Connector RJF21B Mating Cable Connector RJF6G Cable interface Standard RJ45 Web Browser SNMP User Interface Standard AC Input Connector C...

Page 6: ...Crimp Pins and C CL101021 and CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts maximum 2 Neutral 3 Ground 2 2 Message Protocol The serial format for the RS232...

Page 7: ...ternal reference where aaCEx Set 10 MHz reference mode Range 2000 to 2000 x 1 to select RS422 x 0 to unmute the output x 1 to mute the output where aaCMx Set Mute xxxxx 5 characters where aaCOxxxxx Se...

Page 8: ...urns aaSRxx where aaSR RS485 address x 0 if RS232 is selected Returns aaSIx where aaSI Serial Interface x 2 if External 10 MHz reference is selected x 1 if Internal 10 MHz reference is selected Return...

Page 9: ...internal 2 extenal w summary alarm 0 off 1 on returns aaSSwxyz where aaSS returns aaSVxxxxxxxxyyyy where aaSV Model and firmware revision Range 2000 to 2000 xxxxx 5 characters yyyy unit firmware rev x...

Page 10: ...ernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 21T23 2 5 2 Ethernet Configuration Each 4116 21T23 must be configured with an appropriate IP address Netma...

Page 11: ...ger click on Network to display the Network Settings screen Enter the IP address Subnet mask and Gateway address with delimiter dots example 192 168 192 47 Click apply settings in the left frame to ap...

Page 12: ...port 9999 The following instructions explain how to establish such a Telnet connection using Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the...

Page 13: ...NMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of S...

Page 14: ...Figure 2 F Device Server Configuration Menu 4116 21T23 Manual Rev B Page 14 09 24 15...

Page 15: ...arm RF OUT 60 to 0 dBm 2 20 2 30 GHz S Band Output ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector RF INPUT Type N 50 2 02 2 12 GHz S Band Input RF IN MON Type N 50 10MHz INPUT SMA fem...

Page 16: ...onitor and Control Connector Monito Monitor and Control Connector Pinout Conne Connector part number MS3112E14 18S Mating Mating Cable Connector part number MS3116F14 18P Pin Signal Description A Chas...

Page 17: ...al 10 MHz 2 to 8 dBm reference that is inserted at J3 via Ethernet or serial command 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the same level as the input 0 5 dBm J4 See Draw...

Page 18: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 21T23 Manual Rev...

Reviews: