2.0  Installation

2.1  Mechanical - The 284-19 consists of one RF printed circuit board (PCB) housed in a 4.7”W x 1.75”H x 
6.5”D bench top chassis. A 115 VAC, 60Hz wall power supply pr18VDC power for the internal and 
external amplifiers and LEDs. RF connectors are type F, female. The 284-19 can also be secured to a rack using 
the four holes on the optional 1 RU chassis front panel.  Figure 2.1 shows how the 284-19 is assembled. J11 
connects DC Power to the fuses as shown and J12 connects the DC voltage from the power supply to the PCB 
as shown.

FIGURE 2.1    284-19 MECHANICAL ASSEMBLY

WALL POWER 

SUPPLY

1
2

FUSE

J11

POWER SUPPLY J12

2   1

PIN 1, +18VDC
PIN 2, GROUND

PIN 1, LNB SIDE
PIN 2, +18VDC SIDE

284-19 Manual, Rev A

 

  Page 5

    

       07/27/09

Summary of Contents for 284-19

Page 1: ...ry to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from...

Page 2: ...omer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc sha...

Page 3: ...ront panel a green LED indicates the presence of 18 VDC at the LNB power supply output and DC voltage test points allow monitoring this voltage with a voltmeter Presence of power from the 18 VDC wall...

Page 4: ...Frequency Response 1 0 dB 0 95 2 05 GHz 0 5 dB any 20 MHz incr Port to Port Isolation 18 dB min 20 dB typ Indicators Power Green LEDs indicate DC voltage and power to LNB Other LNB DC voltage 18 2 VD...

Page 5: ...type F female The 284 19 can also be secured to a rack using the four holes on the optional 1 RU chassis front panel Figure 2 1 shows how the 284 19 is assembled J11 connects DC Power to the fuses as...

Page 6: ...p Fast Blo 1 4 Fuse J12 DC INPUT 18VDC from wall power supply OUT J1 OUT J2 OUT J3 OUT J4 FIGURE 2 2 284 19 REAR PANEL 2 3 Front Panel Monitors and Indicators Figure 2 3 shows the front panel monitors...

Page 7: ...rear panel fuse holder to insure proper signal and voltage NOTE FOR OPTIMUM PERFORMANCE THE MONITOR PORT AND SPLITTER OUTPUT PORTS SHOULD BE TERMINATED WITH 75 OHM TYPE F TERMINATIONS WHEN NOT USED 2...

Page 8: ...n of the equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the...

Page 9: ...ES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 284 19 Manual Rev A...

Reviews: