![Cross Technologies 2282-122-21 Instruction Manual Download Page 19](http://html1.mh-extra.com/html/cross-technologies/2282-122-21/2282-122-21_instruction-manual_2688692019.webp)
2.5.2 Control Switches
1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing
the Menu/Execute switch and completed by pressing the Menu/Execute switch.
2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor
left or right.
3. Vertical Switch - This switch is mounted so its movement is vertical, and changes settings in each menu.
2.5.3. Power On Settings and LCD Menu
NOTE: The last status of a unit is retained even when power is removed. When power is restored, the unit will
return to it's previous settings.
When power is first applied, the unit will read and display the internal network device’s IP address if any
ethernet options are installed. The model number and current firmware version will then be displayed for
approximately 2 seconds. See figure 2.4 for display formats.
The unit is now operational and ready for any changes the operator may desire. The main display is formatted
such that the first column displays the current drawn by each unit and the second column displays the
attenuation setting for each channel.
2.5.4. Detailed Menu Descriptions
Menu 1: Enable Manual Mode
ENABLE MANUAL R
MODE? YES
Select YES or NO with the UP/DOWN switches. If YES is selected than the unit will instantly be in Manual
switching mode and the next menu will allow the operator to scroll through the three possible switch states
which are: Backup None, Backup CH1, and Backup CH2. If NO is selected than the unit will not be in manual
mode and the next menu will be set CH1 attenuation. Push the PROGRAM/EXECUTE switch to go to the next
menu. Use the LEFT/RIGHT switch to move the cursor to R, then push the PROGRAM/EXECUTE switch to
jump to the SAVE SETTINGS menu.