background image

2.0  Installation

2.1  Mechanical - The 2117-9395 consists of one RF PCB housed in a 1 RU (1 3/4 inch high) by 14 inch deep 
chassis. A switching, ± 12, +24, +5 VDC power supply provides power for the assemblies. The 2117-9395 can 
be secured to a rack using the 4 holes on the front panel.  Figure 2.0 shows how the 2117-9395 is assembled.

PS IN
PIN 1, +12 VDC
PIN 2, +5 VDC
PIN 3, +5 VDC
PIN 4, GROUND
PIN 5, GROUND
PIN 6, -12 VDC
PIN 7, +24 VDC
PIN 8, +24 VDC

POWER 

SUPPLY

    

FIGURE 2.0     2117-9395 Mechanical Assembly

    

2117-9395_Manual 

  

                   Page 5

    

                             09/12/19

Summary of Contents for 2117-9395

Page 1: ...reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment...

Page 2: ...echnologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be li...

Page 3: ...MHz reference signal is connected to the external reference input The 2117 is powered by a 100 240 10 VAC power supply and in a 1 3 4 X 19 X 19 rack mount chassis MODEL 2117 CROSS TECHNOLOGIES INC EXT...

Page 4: ...Resp band 1 5 dB 1 5 dB Frequency Resp 85 MHz 0 75 dB 0 75 dB Frequency Sense n non inverting non inverting LO Characteristics LO Frequency Downconverter 7 70 GHz Upconverter 7 30 GHz Frequency Accur...

Page 5: ...ply provides power for the assemblies The 2117 9395 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2117 9395 is assembled 1 PS IN PIN 1 12 VDC PIN 2 5 VDC PIN 3...

Page 6: ...s external 10MHz reference from J2 J2 J101 J111 UPCON J112 J111 2 00 2 20 IN BNC 40 to 20 RF2 IN RF2 OUT J11 RF1 IN DOWNCON J102 RF2 OUT RF1 OUT EXT REF IN RF OUT AC AC INPUT 100 240 VAC 47 60 Hz Uses...

Page 7: ...n 1 Minus DC input 2 NC 3 Plus DC input 4 NC Shell Ground FIGURE 2 1 2117 9395 Rear Panel I O s FIGURE 2 3 2117 9395 DC1 Pinouts TABLE 2 2 Available Options P48 48 VDC Nominal 36 72 VDC 2 5A max R Red...

Page 8: ...spare fuse in the near slot If a fuse continues to open the power supply is most likely defective 2 4 3 Installing and Operating the 2117 9395 Upconverter 1 Connect a 40 dBm to 20 dBm signal from 2 0...

Page 9: ...amp slow blow Type T 5 mm X 20 mm FUSE DRAWER SPARE FUSE INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 240 V FIGURE 2 3 Fuse Location and Spare Fuse 2117 9395_Manual Page 9...

Page 10: ...ation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit an...

Page 11: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2117 9395_Manual Page 11 0...