background image

1.2   Technical Characteristics

TABLE 1.0 2083-2215 Dual Frequency Translator Specifications*

EQUIPMENT SPECIFICATIONS*
Input Characteristics
Input Impedance/RL

75 

Ω

 /12 dB

Frequency,

1.725-2.175 GHz

Input Level

-10 to -30 dBm

Input 1 dB compression

0 dBm

Output Characteristics
Impedance/RL

75 

Ω

/12 dB

Output 1 dB compression

0 dBm

Output Level, Range

-10 to -30 dBm

Frequency

0.95-1.4 GHz

Channel Characteristics
Gain at band center

 0 dB ±2 dB, fixed

Frequency Response

±1.5 dB, 0.95-1.4 GHz out; ± 0.7 dB, any 36 MHz increment 

Frequency Sense  

Inverting (1.725 GHz Translates to 1.4 GHz, 2.175 GHz 
Translates to 0.95 GHz
)

Intermodulation

<-50 dBC for two carriers each at -13 dBm out

Spurious Response

<-40 dBC, for 1.725-2.175 GHz input to 0.95 to 1.4 GHz out
0.95-1.4 GHz Feedthru  <-30 dBC, min, <-40 dBC, goal 
1.725-2.2 GHz Feedthru <-10 dBC, min, <-20 dBC, goal 
LO rejection <-40 dBm, LO at the output

Synthesizer Characteristics 
LO Frequency 

3.125 GHz

Frequency Accuracy

± 1.0 ppm max

-110

-95

-80

-80

-70

1MHz

100kHz

10kHz

1kHz

100 Hz 

                       dBC/Hz

    Phase Noise @ Freq

Indicators
DC Power; PLL Alarm

Green LED; Red LED

Other 
Connectors

RF in and RF Out, BNC, female, 75 ohm

Connector, Alarm

DB9 - NO or NC contact closure on Alarm

Size 

19 inch, 1RU standard chassis 1.75”H X 16.0”D

Power 

100-240 ± 10% VAC, 47-63 Hz, 15 watts max

 

  

*+10˚C to +40˚C; Specifications subject to change without notice

2083-2215 Manual- Rev B

 

            Page 4

    

             9/08/09

Summary of Contents for 2083-2215

Page 1: ...plicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment...

Page 2: ...gies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable fo...

Page 3: ...e Front panel LEDs light when DC power is applied green and when a PLL alarm occurs red The 2083 2215 is powered by a 100 240 10 VAC power supply and housed in a 1 75 X 19 X 16 1RU chassis MODEL 2083...

Page 4: ...nslates to 0 95 GHz Intermodulation 50 dBC for two carriers each at 13 dBm out Spurious Response 40 dBC for 1 725 2 175 GHz input to 0 95 to 1 4 GHz out 0 95 1 4 GHz Feedthru 30 dBC min 40 dBC goal 1...

Page 5: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Page 6: ...by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2083 2215 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 208...

Page 7: ...t see Table 2 2 FIGURE 2 1 2083 2215 Rear Panel I O s TABLE 2 1 J J10 TABLE 2 1 J10 Pinouts Pin Function 1 Rx 2 Rx RS 232C 3 Tx RS 232C 4 Tx 5 GND 6 Alarm Relay Common 7 Alarm Relay Normally Open 8 No...

Page 8: ...cted and the input level provided The firmware will prevent setting gain and input level outside this range See Section 2 5 Menu Settings 7 Be sure DS6 green DC Power is on and DS2 red Alarm is off Fi...

Page 9: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2083 2215 Manual Rev...

Reviews: