Cross Technologies 2017-03A Instruction Manual Download Page 3

MODEL 2017-03A Up/Downconverter

1.0  General

1.1  Equipment Description 

The 2017-03A L-band Up/Downconverter converts 70 MHz to 950-1525 MHz (Up) and 950-1525 MHz to 70 
MHz (Down) in 1 MHz steps with low group delay and flat frequency response. The 2017-03A has lower RF 
level out of the upconverter and higher RF level into the downconverter than the 2017-03 and is typically used 
to interface an L-band modem to a 70 MHz IF upconverter and downconverter. Multi-function push button 
switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power 
(green), PLL alarm for up and downconverters (red), remote operation (yellow), and Upconverter mute 
(yellow). Gain can be manually adjusted over a -25 to +15 dB range for the upconverter and over a 0 to +50 dB 
range for the downconverter by the front panel multi-function push-button switches. Remote operation allows 
selection of frequency and gain. Parameter selection and frequency and gain settings appear on the LCD 
display. Connectors are BNC female for IF and the optional external reference input and output, and Type F 
female for RF.  A high stability (±0.01ppm) option is also available. It is powered by a 100-240 ± 10% VAC 
power supply and housed in a 1.75” X 19” X 16” 1RU chassis.    

 

MENU

EXECUTE

MODEL 2017

C

ROSS 

T

ECHNOLOGIES INC.

U  F=1525     G=+00
D  F=1525     G=+25

MUTE

UPCONVERTER

DOWNCONVERTER

REMOTE

ALARM POWER

ALARM

UP/DOWNCONVERTER

FRONT PANEL

AC

UPCONVERTER

RF OUT

SSPB FUSE

GND

DOWNCONVERTER

J4

J5

J3

J18

J2

RF IN

10 MHZ REF

10 MHZ

IF IN

EXT REF

F2

LNB FUSE

F1

J1

IF OUT

OUTPUT

INPUT

DS8

DS7

VDC on RF

VDC on RF

J10

AND

MONITOR

CONTROL

1

2

3

4

9

6

7

8

REAR PANEL

Figure 1.1   Model 2017-03A Front and Rear Panels

70 

MHz 
OUT

.95

to 

1.525

 GHz 

IN

1750 MHz

BP

1820

MHz

2.7

to

3.3

GHz

.95 to 1.525 GHz

BP

120 MHz

LP

CONTROLLER

U  F=1525    G=+00.0
D  F=1450    G=+25.0

.95 -1.525 GHz

BP

70 

MHz

IN

.95 

to

1.525 

GHz 

OUT 

1750 MHz

BP

1680

or

1820

MHz

2.7

to

3.3

GHz

REF

REF

REF TO 

UP 

VCOS

var

atten

10MHz*

+24VDC*

10MHz*

+24VDC*

EXT

10MHz*

*OPTIONAL

var

atten

var

atten

INT

10MHz

Figure 1.2    Model 2017-03A Up/Downconverter Block Diagram

2017-03A Manual, Rev. I 

 

                    Page 3

    

                     07/22/19

Summary of Contents for 2017-03A

Page 1: ...Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies In...

Page 2: ...to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies...

Page 3: ...d gain settings appear on the LCD display Connectors are BNC female for IF and the optional external reference input and output and Type F female for RF A high stability 0 01ppm option is also availab...

Page 4: ...baud RS485 option Q Other RF Connectors Type F female see Table 2 2 for connector options IF Connectors BNC female see Table 2 2 for connector options 10MHz Connectors BNC female 50 75 option E Alarm...

Page 5: ...Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 male J10 Pinouts RS 232C 422...

Page 6: ...ers standard 7 characters Option X ddd Tx gain 10 to 30 ee Rx gain 00 to 50 ff Tx input level 10 to 40 10 to 40 dBm L 0 non inverted Receiver L 1 inverted M 0 Receiver synth alarm N 0 Transmitter synt...

Page 7: ...cters Range 10 to 40 10 to 40 dBm Set Receiver Frequency aaC2xxxx where xxxx 4 characters standard 7 characters Option X Range 0950 to 1525 MHz Set Transmit Gain aaC3xxxx where xxxx 2 or 3 characters...

Page 8: ...erloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring App...

Page 9: ...y 16 inch deep chassis A switching 12 5 24 VDC power supply provides power for the assemblies The 2017 03A can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2017 0...

Page 10: ...e places 24 VDC 2 5 amp max on the RF OUT J5 center pin F1 LNB FUSE option L 0 5A Fast Blo 1 4 Fuse installing fuse places 24 VDC 0 4 Amps max on the RF IN J2 center pin LNB FUSE F1 DOWNCONVERTER UPCO...

Page 11: ...2 3 DC1 Pinouts Pin Function 1 Minus DC input 2 NC 3 Plus DC input 4 NC Shell Ground Remote Serial Interface Interface DB 9 Male Protocol RS 232C RS 485 option Q 9600 baud no parity 8 data bits 1 sta...

Page 12: ...presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the no...

Page 13: ...ter Section 1 Connect a 60 dBm to 10 dBm signal to RF In J2 Figure 2 1 2 Connect the IF OUT J1 to the external equipment 3 Connect 100 240 10 VAC 47 63 Hz to AC on the back panel 4 Set the desired inp...

Page 14: ...p slow blow Type T 5 mm X 20 mm FUSE DRAWER SPARE FUSE INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 240 V Figure 2 3 Fuse Location and Spare Fuse 2017 03A Manual Rev I Page...

Page 15: ...Out option E Menu 10 Downconverter Reference Out option E Menu 11 Set RS 485 mode option Q Menu 12 Set RS 485 address option Q Menu 13 View PCB Temperature option T Menu 14 View LNB and or SSPB Curre...

Page 16: ...rator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch...

Page 17: ...gle the display to UP F 145 0 R By using the horizontal rocker switch the cursor can be moved left or right UP F 1450 R NOTE CHANGES DO NOT TAKE PLACE ON FREQUENCY UNTIL YOU GO TO THE SAVE MENU AND IN...

Page 18: ...y is for changing the upconverter input level This is an important setting to optimize spurious and should be made as accurately as possible UP INLVL 20 R Pressing the Up Down switch down will toggle...

Page 19: ...ssing the Up Down switch down will toggle the display digit selected until you have the desired gain NOTE THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS HOWEVER THE VALUE WILL NOT BE STORED UNTIL...

Page 20: ...ect Upconverter Reference Out option E Menu 10 Select Downconverter Reference Out option E Menu 11 Reference Offset option E Menu 12 Set Remote Mode option Q Menu 13 Set RS 485 Address option Q Menu 1...

Page 21: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2017 03A Manual Rev I...

Reviews: