background image

2.2

Rear Panel Input/Output Connectors - 

The input and output connectors on the rear panel are shown in Figure 2.1. 

CAUTION! IF FUSES ARE INSTALLED IN THE Fuse 3 OR Fuse 4 HOLDERS, +22 VDC WILL APPEAR 
ON THE CORRESPONDING SPLITTER INPUT CONNECTOR CENTER PINS.

G N D

J I

J 3

J 4

J 1 9

J 5

J 6

J 7

J 9

J 1 0

J 1 1

J 1 2

J 1 4

J 1 5

O U T

O U T

O U T

O U T

O U T

O U T

O U T

O U T

O U T

IN 

O U T

O U T

O U T

F U S E   F 4

F U S E   F 3

 SPLITTER 2 OUTPUTS
 

Terminate when not used

 1 INPUT

 

 

AC 1 INPUT

           

100-240 ±10%  
VAC 47-60HZ                 
Uses 2 amp Fast         
Blo, 5mm Fuse

AC 2 INPUT

          

100-240 ±10%  
VAC 47-60HZ                
Uses 2 amp Fast         
Blo, 5mm Fuse

A C 1

GND

A C 2

 SPLITTER2 INPUT
 CAUTION!
+22 VDC ON
CENTER PIN

CHASSIS
GROUND

 SPLITTER1 INPUT
 CAUTION!
+22 VDC ON
CENTER PIN

  SPLITTER 1 OUTPUTS
 

Terminate when not used

FUSE FOR LNB2
1 amp Fast Blo, 1/4” Fuse 

FUSE FOR LNB1
1 amp Fast Blo, 1/4” Fuse 

IN

J17

OUT

J16

OUT

J15

OUT

J14

OUT

J13

OUT

J12

OUT

J11

OUT

J10

OUT

J9

IN

J19

OUT

J8

OUT

J7

OUT

J6

OUT

J5

OUT

J4

OUT

J3

OUT

J1

OUT

J2

FIGURE 2.1 1584-29 REAR PANEL

2.3

Front Panel Monitors and Indicators -

Figure 2.2 shows the front panel monitors and indicators. 

RF2 - MONITOR
Monitors Splitter 
2 output

POWER LED A
Lights green when DC voltage 
is present from AC A power 
supply.

LNB2   VOLTAGE LED
Lights Green when LNB voltage 
is present on the Splitter input

A

AC POWER

B

LNBVOLTAGE

O N

GND +DC

MODEL 1584

POWER DIVIDER

C

ROSS

 T

ECHNOLOGIES INC.

MONITOR 1

RF

LNB VOLTAGE

O N

GND

+DC

MONITOR 2

RF

POWER LED B
Lights green when DC voltage 
is present from AC B power 
supply.

GROUND
TEST POINT

LNB 2 VDC
TEST POINT

LNB1 VOLTAGE LED
Lights Green when LNB voltage 
is present on the Splitter input

GROUND
TEST POINT

LNB 1 VDC
TEST POINT

RF1 - MONITOR
Monitors Splitter 1 output

FIGURE 2.2 1584-29 FRONT PANEL

1584-29 Manual, Rev C 

 

 Page 7

    

              3/7/19

Summary of Contents for 1584-29

Page 1: ...ies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to in...

Page 2: ...s Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be...

Page 3: ...ltage transients All splitter outputs are AC coupled so no DC appears on their center conductors On the front panel green LEDs indicate presence of 22 VDC at each LNB power supply output and DC voltag...

Page 4: ...Isolation 18 dB min 20 dB typ Coupler to Coupler Isol 35 dB min 40 dB typ Indicators Power Green LED indicates DC voltage prior to diode OR and to amplifiers Other LNB DC voltage 22 2 VDC Output Ampl...

Page 5: ...e equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Page 6: ...1584 29 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 1584 29 is assembled J27 and J25 connect DC Power to the fuses as shown and J30 and J29 connect the DC vo...

Page 7: ...t Blo 1 4 Fuse FUSE FOR LNB1 1 amp Fast Blo 1 4 Fuse IN J17 OUT J16 OUT J15 OUT J14 OUT J13 OUT J12 OUT J11 OUT J10 OUT J9 IN J19 OUT J8 OUT J7 OUT J6 OUT J5 OUT J4 OUT J3 OUT J1 OUT J2 FIGURE 2 1 158...

Page 8: ...nstalled in the rear panel fuse holders to insure proper signals and voltages NOTE FOR OPTIMUM PERFORMANCE THE MONITOR PORT AND SPLITTER PORTS SHOULD BE TERMINATED WITH 75 OHM TYPE F TERMINATIONS WHEN...

Page 9: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1584 29 Manual Rev C Page...

Reviews: