2.2
Rear Panel Input/Output Connectors -
The input and output connectors on the rear panel are shown in Figure 2.1.
CAUTION! IF FUSES ARE INSTALLED IN THE Fuse 3 OR Fuse 4 HOLDERS, +22 VDC WILL APPEAR
ON THE CORRESPONDING SPLITTER INPUT CONNECTOR CENTER PINS.
G N D
J I
J 3
J 4
J 1 9
J 5
J 6
J 7
J 9
J 1 0
J 1 1
J 1 2
J 1 4
J 1 5
O U T
O U T
O U T
O U T
O U T
O U T
O U T
O U T
O U T
IN
O U T
O U T
O U T
F U S E F 4
F U S E F 3
SPLITTER 2 OUTPUTS
Terminate when not used
1 INPUT
AC 1 INPUT
100-240 ±10%
VAC 47-60HZ
Uses 2 amp Fast
Blo, 5mm Fuse
AC 2 INPUT
100-240 ±10%
VAC 47-60HZ
Uses 2 amp Fast
Blo, 5mm Fuse
A C 1
GND
A C 2
SPLITTER2 INPUT
CAUTION!
+22 VDC ON
CENTER PIN
CHASSIS
GROUND
SPLITTER1 INPUT
CAUTION!
+22 VDC ON
CENTER PIN
SPLITTER 1 OUTPUTS
Terminate when not used
FUSE FOR LNB2
1 amp Fast Blo, 1/4” Fuse
FUSE FOR LNB1
1 amp Fast Blo, 1/4” Fuse
IN
J17
OUT
J16
OUT
J15
OUT
J14
OUT
J13
OUT
J12
OUT
J11
OUT
J10
OUT
J9
IN
J19
OUT
J8
OUT
J7
OUT
J6
OUT
J5
OUT
J4
OUT
J3
OUT
J1
OUT
J2
FIGURE 2.1 1584-29 REAR PANEL
2.3
Front Panel Monitors and Indicators -
Figure 2.2 shows the front panel monitors and indicators.
RF2 - MONITOR
Monitors Splitter
2 output
POWER LED A
Lights green when DC voltage
is present from AC A power
supply.
LNB2 VOLTAGE LED
Lights Green when LNB voltage
is present on the Splitter input
A
AC POWER
B
LNBVOLTAGE
O N
GND +DC
MODEL 1584
POWER DIVIDER
C
ROSS
T
ECHNOLOGIES INC.
MONITOR 1
RF
LNB VOLTAGE
O N
GND
+DC
MONITOR 2
RF
POWER LED B
Lights green when DC voltage
is present from AC B power
supply.
GROUND
TEST POINT
LNB 2 VDC
TEST POINT
LNB1 VOLTAGE LED
Lights Green when LNB voltage
is present on the Splitter input
GROUND
TEST POINT
LNB 1 VDC
TEST POINT
RF1 - MONITOR
Monitors Splitter 1 output
FIGURE 2.2 1584-29 FRONT PANEL
1584-29 Manual, Rev C
Page 7
3/7/19