2.4
Operation
1. Set the on board controls as desired (Tables 2.2, 2.3, Figure 2.3).
2. Install the 1582-650 in the equipment rack.
3. Connect RF to the Type N connectors (J1,J2,J3).
4. Connect to signals on the MONITORS AND CONTROLS connector, J7, as desired,
(see Figure 2.2, Table 2.1).
5. Connect power via two power cords to AC1 and AC2.
6. Manually switch between channels 1 and 2 and be sure switching occurs.
7. Switch to AUTO. Alarm channel 1 and note that automatic switching occurs. Remove alarm to CH1
and note that the output switches as desired. Push RESET if in LATCH mode. Repeat for CH2.
8. Check that CH1 and CH2 are selected when in AUTO and momentary ground is applied to J7 pins
1 and 2 Momentarily ground Remote Reset pin 4 on J7 if in LATCH mode to return to AUTO operation.
FUSE DRAWER
SPARE FUSE DRAWER
AC Fuse - 2 amp slow blow (Type T),
5 mm X 20 mm
~
INPUT
100-240± 10%VAC
47-63 Hz
2A MAX
FUSE
TYPE T 2A GDC
250 VOLT
FOR 100 - 240 V~
~
FIGURE 2.4 Fuse and Spare Fuse Locations
1582-650 Manual, Rev. C
Page 8
01/26/10