2.6  Environmental Use Information

A

.

Rack-Mounting 

- To mount this equipment in a rack, please refer to the installation instructions 

located in the user manual furnished by the manufacturer of your equipment rack.

B. Mechanical loading

 - Mounting of equipment in a rack should be such that a hazardous condition 

does not exist due to uneven weight distribution.

C

.

Elevated operating ambient temperature 

- If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack may be greater than room ambient temperature.  
Therefore, consideration should be given to Tmra.

D. Reduced air flow

 - Installation of the equipment in a rack should be such that the amount of air flow 

required for safe operation of the equipment is not compromised.  Additional space between unit 
may be required.

E. Circuit Overloading 

- Consideration should be given to the connection of the equipment to the supply 

circuit and the effect that overloading of circuits could have on over current protection and supply wiring.  
Appropriate consideration of equipment name plate rating should be used, when addressing this concern.

F. Reliable Earthing

 - Reliable earthing of rack-mounted equipment should be maintained.  Particular 

attention should be given to supply connections other than direct connection to the Branch 
(use of power strips).

G. Top Cover

 - There are no serviceable parts inside the product so, the Top Cover should not be removed.  

If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED 
prior to Top Cover screw replacement.  FAILURE TO DO this may cause INGRESS and/or EGRESS 
emission problems.

1582-03 Manual, Rev. C

 

 

 Page 10

    

    4/13/09

Summary of Contents for 1582-03

Page 1: ...in are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from...

Page 2: ...Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall no...

Page 3: ...nel Select ICS Mode Switch stays on channel last selected by Manual or Remote selection after return to AUTO AUTO switching occurs only if current channel alarms and other channel is clear If power is...

Page 4: ...h to CH1 if it is good and switch is in the latch mode Also Resets REMOTE by returning operation to AUTO Indicators LEDs CH1 ON LINE Turns green when Channel 1 is selected CH2 ON LINE Turns green when...

Page 5: ...t connectors AC1 AC2 DATA 2 1 J8 GND DATA 1 DATA OUT J103 J107 J106 AC1 POWER IN 1 1 5 A FUSE AC2 POWER IN 2 1 5 A FUSE J106 DATA 1 J107 SWITCHED DATA J103 DATA 2 J8 CONTROLS FIGURE 2 0 1582 03 REAR P...

Page 6: ...Remote to Auto REMOTE INDICATION 15 Open collector output 5 to gnd when in REMOTE mode MANUAL INDICATION 8 Open collector output 5 to gnd when in MANUAL mode SWITCH 1 MON 11 Relay closure to J8 pin 6...

Page 7: ...times out or on external alarm input REMOTE LED Turns amber when REMOTE control is active MANUAL SELECT 3 position switch as follows LEFT manually select Channel 1 center Auto switch position determin...

Page 8: ...o the connection of the equipment to the supply circuit and the effect that overloading of cicuits could have on overcurrent protection and supply wiring Appropriate consideration of equipment namepla...

Page 9: ...2 Momentarily ground remote Reset pin 4 on J8 to return to Auto operation FUSE DRAWER SPARE FUSE DRAWER AC Fuse 2 amp slow blow Type T 2A GDC 5 mm X 20 mm INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TY...

Page 10: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Page 11: ...HNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1582 03 Manual Rev C Page 1...

Reviews: